89
3.
C
on
ne
cting with the Contro
ller
3. Connecting with the Controller
As the connection cable for the controller and RCP6W/RCP6SW (this actuator), use the
IAI-dedicated controller and dedicated connection cable.
This section explains the wiring method for a single axis.
If the dedicated connection cable cannot be secured, reduce the load on the cable by allowing it
to deflect only by the weight of the cable or wire it in a self-standing cable hose, etc., having a
large radius.
Do not cut and reconnect the dedicated connection cable for extension or shorten the cable.
Do not pull on the dedicated connection cable or bend it forcibly.
The actuator cable coming out of the motor unit is not meant to be bent. Fix the cable so it would
not be bent repeatedly
Please consult with IAI if you require a different kind of cable than the one supplied.
Dedicated Controller
Dedicated Cable
RA4, RA6, RA7
ꞏ Motor Encoder Integrated Cables: CB-CAN-MPA□□□
ꞏ Motor Encoder Integrated Robot Cables:
CB-CAN-MPA□□□-RB
RA8
ꞏ Motor Encoder Integrated Cables: CB-CFA3-MPA□□□
ꞏ Motor Encoder Integrated Robot Cables:
CB-CFA3-MPA□□□-RB
* □□□ represents the cable length. The longest corresponds to 20m.
Note that the maximum length of motor/encoder cable and actuator cable combined
is 20m.
e.g.) 080 = 8m
ꞏ PCON-CB/CGB
ꞏ PCON-CYB/PLB/POB
ꞏ PCON-CFB/CGFB
ꞏ MCON
ꞏ MSEL
アクチュエータ
ケーブル
モータ・エンコーダ
ケーブル
Actuator
Cable
Motor/Encoder
Cable
RCP6W- ××
Robot Cable
: 5m or below
(Note 1)
r = 68mm or more (movable use)
: In the case of exceeding 5m
(Note 2)
r = 73mm or more (movable use)
Standard Cable
: 5m or below
(Note 1)
r = 85mm or more (fixed use)
: In the case of exceeding 5m
(Note 2)
r = 91mm or more (fixed use)
Note 1 CB-CFA3-MPA□□□(-RB) is 3m or less.
Note 2 When CB-CFA3-MPA□□□(-RB) is over 3m.
Dedicated Connection Cable
(Connect RCP6W and dedicated controller)