![ROBO Cylinder RCP6SW Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/robo-cylinder/rcp6sw/rcp6sw_instruction-manual_1470818017.webp)
9
10. For actuator front bracket end face mounting with the rod upward, provide a
drain groove so that liquid does not accumulate in the scraper part of the
front bracket.
A drain groove is provided on the front flange (option setting). Be careful not to block the drain groove
when mounting components.
11. Grease gradually flows outside from the rod.
Grease gradually flows out in order to maintain lubrication on the scraper. Protect the peripheral
equipment if there is a risk of grease adhesion.
12. The degree of protection is IP65 (dust-resistant/jet-proof).
“Jet-proof units” refers to products which, even after being subjected to 3 minutes of direct water
jets in the prescribed method, will incur no entry of water harmful to normal device operation or
safety. The unit may be damaged in an environment where there are constant water jets. Please
take appropriate protective measures.
13. For PCON-CB, RCON-PC and MCON Controllers (with option: T),
parameter setting can be used to switch the high-output setting between
enabled and disabled; please use with the high-output setting enabled.
(In the setting at delivery, the high output setting is set to effective.)
For MSEL Controller, the high output setting is effective and cannot switch it over to ineffective.
[Refer to an instruction manual for each controller for details]
Controller
Parameter
Remarks
PCON-CB
RCON-PC
No.152 High Output Setting
[0: Ineffective, 1: Effective]
MCON
No.152 High Output Setting
[0: Ineffective, 1: Effective]
Option T: In high output setting, available to
have high output setting effective.
14. The RCP6SW with built-in controller specification does not have a port for
teaching tool connection.
Connect a teaching tool to the gateway unit and set position data, etc., via the gateway unit.
スクレーパ
ドレーン溝
フレーム
フロントフランジ
Front flange
Scraper
Drain
groove
Frame