FL150-3 User Manual
Page 09
5 . 2 R e p l a c e m e n t s t a s k s a n d e x p l a n a t i o n s
Component
Tasks and explanation
Replace period Operator
A. Lamp replacement
Before replacing the lamp, please make sure that
the unit is switched OFF. Allow it to cool off.
Please take the following steps:
1.
Remove the lid.
2.
Disconnect the lamp.
3.
Release the lamp plug and lift out the lamp.
4.
Install a new lamp, reversing the procedure.
See the instructions on the light generator !!!
By lamp defect
or after 6,000
operating hours
Retailer
B. Fan / ventilator
replacemnet
Changing the fan is easily done. It is only
necessary to release one Allen screw
Please take the following steps:
1.
Remove the screw at the back. Use Allen Key.
2.
Tip the back plate out, starting from the top.
3.
Remove the bracket from the hinge.
5.
Release the fan from the bracket.
6.
Release the fan plug from the light generator.
7
. Install a new fan by reversing 1 to 5.
8
. Make sure that the fan runs freely after instal-
ling again.
When defective
Retailer
C. Supply fuse
replacement
The supply fuse is placed in the mains supply
socket. The fuse is exchanged by releasing the
fuse drawer from the mains supply socket and
removing the fuse from here. Use Ø 5X20mm
type 5 AT.
When defective
Retailer