FL150-3 User Manual
Page 08
Component
Tasks and explanation
Inspection
period
Operator
D. Light generator
glass filters
Inspect and clean the glass filters and if
necessary change.
The glass filters and the harness common end
of the fiber optics should be wiped with a dry,
lintfree cloth when cold.
Change the filters if the glass is broken or
cracked.
Note: do not use alcohol or any other solvent
to clean the fibre harness common end.
Please take the following steps:
1.
Take out the lamp
2.
Release the filter system that keeps the lamp
in place.
3.
Jiggle out the filter system by pulling the
bracket towards the back of the generator and
take it out of the box.
4.
Clean the filters (Remove the filters from the
bracket by releasing the spring clip that holds
the filters.The filters´ relative position should
be observed when reinstalling). The thick
filter must always be placed closest to the fiber
end.
5.
Install the filters and the lamp by reversing the
above procedure.
The same procedure may be used when
installing an optional dichroic colour filter.
Note: The generator can not be used without
filters! Filters and surrounds can never be
inserted the wrong way.
Twice a year
and always
when you
change the
lamp
Retailer
E. Light generator
fiber connection
Inspect and clean the fibre connection
surface.
Clean the fiber harness common end with a
damp lintfree cloth,
but do not touch it with the
fingers.
If the surface looks burnt, has black dots on it
or looks yellow please inform Fiber Optics sales
representative. Further action will then be taken.
Note: Do not bend or pull the cable, as the
harness may be fix connected with the
cabinet.
Always when
you change the
lamp
Retailer