9
Recommendations and
suggestions
• The Instructions for Use apply
to several versions of this appli-
ance. Accordingly, you may find
descriptions of individual features
that do not apply to your specific
appliance.
• The manufacturer will not be
held liable for any damages re-
sulting from incorrect or improper
installation.
• The minimum safety distance
between the cooker top and
the extractor hood is 650 mm
(some models can be installed
at a lower height, please refer
to the paragraphs on working
dimensions and installation).
• Check that the mains voltage
corresponds to that indicated
on the rating plate fixed to the
inside of the hood.
•
For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
Connect the extractor to the
exhaust flue through a pipe of
minimum diameter 120 mm.
The route of the flue must be
as short as possible.
• Do not connect the extractor
hood to exhaust ducts carrying
combustion fumes (boilers, fire
-
places, etc.).
• If the extractor is used in
conjunction with non-electrical
appliances (e.g. gas burning
appliances), a sufficient degree
of aeration must be guaranteed
in the room in order to prevent
the backflow of exhaust gas. The
kitchen must have an opening
EN
communicating directly with the
open air in order to guarantee
the entry of clean air. When the
cooker hood is used in conjunc-
tion with appliances supplied with
energy other than electric, the
negative pressure in the room
must not exceed 0,04 mbar to
prevent fumes being drawn back
into the room by the cooker hood.
• The air must not be discharged
into a flue that is used for ex
-
hausting fumes from appliances
burning gas or other fuels (not
applicable to appliances that
only discharge the air back into
the room).
• In the event of damage to the
power cable, it must be replaced
by the manufacturer or by the
technical service department, in
order to prevent any risks.
• If the instructions for installation
for the gas hob specify a greater
distance specified above, this
has to be taken into account.
Regulations concerning the dis-
charge of air have to be fulfilled.
• Use only screws and small parts
in support of the hood.
Warning:
Failure to install the
screws or fixing device in ac
-
cordance with these instructions
may result in electrical hazards.
• Connect the hood to the mains
through a two-pole switch having
a contact gap of at least 3 mm.
Use
• The extractor hood has been de-
signed exclusively for domestic
use to eliminate kitchen smells.
• Never use the hood for purposes
Содержание 5067010