Z500-serie
V0818
27
English
Deutsch
Use of the parallel fence
(Fig.24A-B)
When the serrated knob (3) is unlocked and the handle (1) is lifted up, the complete parallel fence can
be moved. To lock the fence in position push the handle (1) down.
The micrometric adjustment is achieved by locking the knob (3), by holding the handle (1) in the
upright position and by turning the serrated knob (2).
After the adjustment, push handle (1) down to lock the fence in place. When cutting small workpieces
with the saw unit inclined at 45°, the fence should be used in the low position.
Simply unlock the eccentric clamping handle (4), slide off the fence and slide it back on in the low
position. Lock the fence with the eccentric clamping handle (4).
When cutting solid wood using the parallel fence, to avoid the wood getting stuck between the fence
and the riving knife (resulting in a highly dangerous kickback) it is recommended to reposition the
fence so that its end protrudes just past the end of the riving knife.
Fig.24A
Fig.24B
Calibration of the scale on the parallel
fence
(Fig.23-25)
Each time a new sawblade is fitted the parallel fence scale has to be calibrated to the new sawblade.
By cutting a sample and measuring its exact length, the scale can be adjusted so that the exact
measure corresponds with the front side of the fence.
After the screw (1) has been loosened the scale can be adjusted. To avoid the fence contacting the
sawblade while it is revolving, the stop ring (2) has to be adjusted. Slide the fence to about 10 mm
from the sawblade. Now slide the stop ring (2) across the round guide bar (3) until it comes up against
the casting of the fence. Tighten the lock screw on the stop ring.
For a digital reading: Move the parallel fence against the saw blade, and then simultaneously press
the “F” and “SET” buttons. The value on the digital reading jumps to “0”.
Then shift the locking ring (fig. 25.3) onto the saw guide (2) until the cutting width is limited to 2 mm.
This prevents inadvertent contact with the saw blade.
If the size display is not correct when the digital display is read, check the distance between the
sensor (Fig. 23.2) and the digital measuring tape (Fig. 23.1). This may be max 0.2 mm. If necessary,
adjust this with the adjusting bolts (fig. 23.3).
Содержание Z500 EL
Страница 26: ...26 V0818 Z500 serie English Deutsch Fig 19 Fig 20 Fig 21...
Страница 32: ...32 V0818 Z500 serie...
Страница 58: ...58 V0818 Z500 serie English Deutsch Fig 19 Fig 20 Fig 21...
Страница 64: ...64 V0818 Z500 serie...