Z500-serie
V0818
25
English
Deutsch
Mounting of the cross-cut fence
(Fig.18A-B)
To place the cross-cut fence on the cross-cut table, place the fence with the right hinge pin (1) in the
fastening hole on the front of the table (fig. 18B). Now place the clamping screw (2). Slide the fence
backwards until the stop bolt (3) is securely in the rear support point (4) and the stop bolt (5) in the
support point. These support points also serve as a 90 ° stop. The support point (4) is set fixed but
can be adjusted if desired, but it does not serve to adjust the squareness of the fence, this is done
with 4 adjusting bolts (fig 17, 2), but to adjust the rear fastening point without play. The fence can be
used in 2 positions at the front or the rear, and at an angle.. All attachment points are factory-set.
There is an index system for the fence. This allows you to cut accurately at an angle and have a
correct length reading on the fence. Loosen the 3 clamping screws loosely, push the stop beam
forward so that it is free from the support point (4). Now the fence can be moved at an angle. The
angle can be read on the measuring scale (7). Now pull the fence backwards until the stop (5)
falls into one of the notches on the index plate (8). Now you are sure of angle and length. Now the
clamping screws (2 and 6) can be fixed again.
Fig.18A
Fig.18B
Adjusting the cross-cut fence
(Fig.19-20-21)
ATTENTION!
To move the flip stop, loosen the clamping lever (2) at maximum ¼ turn. If it is further
loosened, the digital readout can lose its signal and thus indicate wrong values.
All measuring tapes are factory calibrated and the measure is read directly at the index (fig. 19.1).
The optional digital read out, or the normal standard stop, is calibrated as follows: put the 300 mm
calibration gauge
(Z1253) against the cross-cut fence and the saw blade tooth.
Now slide the digital stop up against the gauge and push << F and SET >>.
The read out is now automatically set at 300mm.
In order to check if the normal measuring tape matches the 300 mm at the index (fig.19, 1),
Make a test cut by putting both flip stops at any given position and check if the obtained measures
are correct.
When using the telescopic part of the cross-cut fence (up to 3360 mm) unlock the handle (fig.20.1)
And slide out the extension. Reading is done on the fixed part of the cross-cut fence, or on the
optional digital read out.