Thicknesser feed (fig. 7)
The machine is equipped with an frequency variator thus enabling an feeding speed
of 5 to 22 m/min.
The feeding motor is started-up by pushing the button of the potentiometer POT, and
by turning the same button a feeding speed can be selected between 5 and 22 meter
per minute, changing over from one speed to an other can be done without having to
stop the feeding motor.
In case of overloading of the feeding mechanism the feeding motor must be
disengaged immediately by pushing the button of the potentiometer POT and the
main cutterblock motor by pushing the emergency stop button (fig. 3, AU1) on the
switch panel.
After reducing the depth of cut on the thicknesser, the motor can be started up again.
fig.7
Emergency stop
Potentiometer feeding speed
Feeding speed reset in case of
overload
Feeding speed frequency
variator warning light
Main motor start