Robitronic
Pro-Master Manual
Operating Instructions
4
Pro-Master operating instructions
Setup
Using the motor checking function requires a 12-volt lead-acid battery with a capacity of at least
17 Ah but not much more. We recommend a Panasonic lead-acid battery Type LC-RC1217PG.
Do not use a lead-acid battery with more than 40Ah !!!
Do not charge the lead-acid battery during a motor-check !!!
If you use a big automotive battery and check a motor with 11 turns or less the power limit of the
Pro-Master will be reached. (Pro-Master message: „High Power“). In this case you must use a
battery with less capacity.
Don´t try a bigger one !!!!!
For the battery charging function you can instead use a stabilized power supply delivering 5-10
amperes. Connect the supply voltage with the battery clips of the Pro-Master main unit. See
instructions on page 6 and the assembly sketch on page 7.
Pro-Master allows you to change the default parameters (see page 12) such as battery simulation
voltage, and the default values can be reset by pressing the [START] key while connecting the
supply voltage.
Pro-Master keys and operation
Description of keys:
[Mode]
selection key
[Start]
activation key
[+]
modification key (increase value)
[-]
modification key (decrease value)
Key functions on selection of a function (menu item)
The
[Mode]
key allows selection of a function from the menu.
Pressing the
[Start]
key activates the selected function.
Key functions for setting values
The
[Mode]
key allows selection of a value; a small bar under a value marks the selected
parameter.
The
[+]
and
[-]
keys allow modification (increase or decrease, respectively) of the selected
value.
Pressing the
[Start]
key saves the modified values and terminates setup.