Installation Instructions
Electrical Connection
Local Authority Requirements
Installation is only permitted by an authorized person, and carried out according to
instructions provided by the manufacturer. Incorrect installation might cause harm and
damage which the manufacturer accepts no responsibility.
Electrical Installation
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped
on the appliance identification plate) must be checked for correspondence to the available mains
supply voltage, and the mains electric wiring should be capable of handling the oven’s power rating
(also indicated on the identification plate).
NOTE
: For connections to the mains power supply, never use adapters, reductions or multiple
power points as these may overheat and catch fire.
After having installed the appliance, the switched outlet must always be in an accessible position.
The electrical safety of this appliance can only be guaranteed if the oven is correctly and efficiently
earthed. The manufacturer declines all responsibility for damage resulting from a system which has
not been earthed.
WARNING
: If any damage occurs to the power cable during or after installation, it must be replaced
immediately by a licensed electrician with a replacement cable from your Service Centre.
The appliance is to be connected to a single phase 220-240Vac 50 Hz supply.
The appliance is designed for fixed connection to the mains. Means for disconnection with a
suitable - isolating switch must be incorporated in the fixed wiring in accordance with the wiring
rules. The power supply cord must not touch against any hot surfaces and must be placed so that its
temperature does not exceed 75 °C at any point along its length.
Wire cross-sectional
area(mm2)
Connection mode
L1
N
E
Single phase 1N~
Minimum 4mm
Minimum 4mm
Minimum 4mm
6