Pre-installation

Thank you for purchasing a quality Robinhood rangehood.  Robinhood has a high standard of quality control and every 

rangehood is tested and approved before it leaves the factory.

Important:

Please read the entire instructions before installing the rangehood, always switch power off prior to installation.

All electrical work must be done by a registered electrician in accordance with local and national electrical codes 

as applicable. For your safety, this product must be earthed.

The power socket must be accessible and enable the end user to isolate the rangehood from the power for the 

purpose of internal cleaning or maintenance.

A power outlet should be within 1500mm of the power cord exit from the rangehood.

The canopy hood is not intended for use by persons (including children) with reduced physical, sensory or metal 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety

Children should be supervised to ensure that they do not play with the appliance.

There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances 

burning gas or other fuels.

There is a fire risk if cleaning is not carried out in accordance with the instructions. You must read the details 

concerning the method and frequency of cleaning.

Do not flambé under the rangehood.

Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances 

burning gas or other fuels.

The minimum distance between the hob surface and the lowest part of the rangehood is 600mm. This distance 

shall be at least 650mm, if the rangehood is installed over a gas hob.  If the instructions for the gas hob specify 

a greater distance, this has to be taken into account.

Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is 

fulfilled. If re-circulating, ensure that the side outlet grilles on the upper chimney are not obstructed.  Even a 

partial obstruction will restrict the efficiency of the rangehood.

Stainless steel is very easily damaged during installation if abraded or knocked by tools.  Protect the rangehood 

with the cardboard box or plastic bag during installation.

Check the contents of the packaging, check all electrical functions of the canopy before installation. 

Canopy is heavy. Please ensure adequate care when installing to prevent personal injury.

CAUTION: Accessible parts may become hot when used with cooking appliances

Содержание RHCP9G

Страница 1: ...Description ROBINHOOD WALL CANOPY GLASS 90CM PLATTO Model Numbers RHCP9G Product may vary slightly from the picture Issue G ...

Страница 2: ...e same time as appliances burning gas or other fuels There is a fire risk if cleaning is not carried out in accordance with the instructions You must read the details concerning the method and frequency of cleaning Do not flambé under the rangehood Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels The minimum dist...

Страница 3: ... 750mm above the cooking surface Ascertain the desired installation height of the canopy hood Any installation above 750mm will compromise the extraction performance The air outlet from the motor requires 150mm round ducting which requires 170mm diameter hole in the ceiling A 650mm electric cook top min A 650mm gas cook top min B 305mm C 220mm ...

Страница 4: ... configurations through the top of the home for the roof and soffit and through the rear of the home 150mm round ducting should be used in conjunction with this model rangehood Alternatively this rangehood can be operated in recirculation mode Pg 6 Recirculation mode The highlighted area in the table below gives the recommended Uniduct item numbers for different mounting and outlet options Extra l...

Страница 5: ...nd purchase a charcoal filter For other accessories parts and service please contact your local supplier or approved service agent Ducted For ducted installation it is recommended you use 150mm diameter rigid semi rigid ducting this will require a 170mm hole in the ceiling wall Before drilling any holes check the area behind the surface to be drilled is clear of any electrical cables pipes etc Not...

Страница 6: ...olds the oil cup in place under the motor unit and fit the filters Cleaning and maintenance Particular care must be taken with the aluminium filters which must be periodically cleaned at least every two months Remove the grease filters and wash them either by hand using hot soapy water or in the dishwasher using mild detergent Note some discolouration of the frame may occur Caution Never use abras...

Страница 7: ...e discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels The minimum distance between the hob surface and the lowest part of the rangehood is 600mm This distance shall be at least 650mm if the rangehood is installed over a gas hob If the instructions for the gas hob specify a greater distance this has to be taken into account Attention should...

Страница 8: ...each mentholated spirits drain cleaners sugar soap metal pads and strongly alkaline or acidic cleaners Heat damage including from washing the product at high temperatures Impact or mishandling the product including the impact caused by objects scraped along thrown or dropped on the product surface or excessive weight being placed on the product Structural or support changes in or affecting the bui...

Страница 9: ... Pty Ltd ABN 83 004 568 138 Telephone 1800 648 556 Facsimile 1800 628 577 Email enquiries robinhood com au www robinhood com au Attention Customer Services Manager Warranty exclusions 1 The warranty does not apply where in Parbury s opinion The defect is caused by misuse wear and tear dirt fire or accidental damage The product has been repaired or serviced by an unauthorised person The product was...