Ventilation
• Ventilation must be in accordance with AS5601-2010
Gas Installations.
• The appliance should have adequate ventilation for complete combustion of gas, proper fluing and to maintain
temperature of immediate surroundings within safe limits.
Discharging Products of Combustion
• Extractor hoods connected directly to the outside must be provided to allow safe discharge of combustible gas (fig.16).
• If this is not possible an electric fan attached to an external wall or the window may be used, the fan should have a
capacity to circulate air at an hourly rate of 3-5 times the total volume of the kitchen (fig.17).
• The fan can only be installed if the room has suitable vents to allow air to enter (fig.17).
GAS SECTION
Gas Types
This appliance is approved for use with:
• Universal LPG – 2.75kPa
• Natural Gas – 1.0kPa
(Commissioning test point pressure is with all burners on large flame.)
Gas Connection
The appliance is predisposed and adjusted to operate with the gas indicated on the gas type label applied to the
underside of the appliance.
This appliance is pre-set at the factory for Natural Gas.
If the appliance must be operated with a gas different than that indicated on the gas type label, it is necessary to execute the
following gas conversion operation:
• Remove gas type label.
•
Replace the injectors to suit the gas type (see nozzle table contained in this manual).
•
Apply gas type label provided with the conversion kit.
•
Adjust the operating pressure to suit the gas type.
•
Regulate the bypass adjustment screw to set the minimum gas rate.
•
To adjust the minimum flame setting, use a screw driver on the screw placed on the tap after removing the control
knob. Turn the tap to its minimum setting and turn the screw to adjust (for LPG turn the screw tight).
THIS SHOULD ONLY BE CARRIED OUT BY AUTHORISED PERSONNEL!