Installation
Regulating the Burner Minimum Setting
When switching from one type of gas to another, the minimum flow rate must be correct so that the flame will not go when
changing from maximum to minimum flame.
To regulate the flame follow the instructions below:
• Light the burner then turn the knob to low flame.
• Adjust the bypass screw to set the minimum flame.
For gas valves with bypass adjustment screw in the centre of the shaft (fig.21)
•
Using a screwdriver with maximum diameter 3mm, turn the screw inside the tap until the correct setting is obtained.
For gas valves with bypass adjustment screw on the valve body (fig.22)
•
Turn the screw (A) to the correct setting with a screwdriver.
ELECTRICAL SECTION
Installation must be carried out according to instructions provided by the manufacturer.
The manufacturer accepts no responsibility for harm or damage to people, animals or objects caused by incorrect
installation.
Connection to the electric power supply must be carried out by a qualified technician following the appropriate
safety regulations.
Before carrying out the connection to the power supply, the voltage rating of the appliance must be checked for
correspondence to the available mains supply voltage, the mains electric wiring should also be capable of
handling the hob’s power rating.
The power point must be connected to suitable earth wiring to conform to current safety regulations.
The power supply cord must not touch against any hot surfaces and must be placed so that it’s temperature does
not exceed 75
°C at any point along it’s length.
The power switch or plug must be in an accessible position.
If the appliance is supplied without a plug a standard plug may be fitted. Be aware that the wiring colours in the hob
cable may differ from the colours of your electrical plug. In any case the plug should be wired as follows:
• Connect the green/yellow wire to the terminal marked with the letter E or the earth symbol.
• Connect the blue wire to the terminal marked with the letter N or coloured black.
• Connect the brown wire to the terminal marked with the letter L or coloured red.