Orientation of the Elbow
This appliance is supplied with a Gas Inlet elbow connection located below the maintop, at the rear. The actual location by
measurement is 110mm from the right hand side of the 4 burner hob, and 50mm from the left hand side of the 5 burner hob.
The connection to the gas supply must be effected only from this side or in vertical position by turning the elbow downwards.
To turn the elbow, follow the directions below:
• Loosen the nut.
• Turn the elbow.
• Lock the nut.
• Never attempt to turn the elbow without having first slackened off the relative lock nipple.
• Make sure that there are no gas leaks by testing with a soapy solution.
• The seals are the elements that guarantees the seal in the gas connection.
• It is recommended they be replaced whenever they show even the slightest
deformation or imperfection.
The gas connection is male ½” BSP.
The hotplate can be connected to the gas supply using rigid pipe OR a flexible hose assembly which is AGA certified to
AS/NSZ 1869, 10mm ID, class B or D and the length must not exceed 1.2m.
WARNING!
Ensure the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or other appliance that is installed
underneath or next to the hotplate.
Ensure the hose assembly is restrained from accidental contact with the flue or flue outlet of an under bench oven.
The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along
its entire length.
• The supply connection point shall be accessible with the appliance installed.
• After connecting to the mains, check that the couplings are tight. Never use a naked flame to check for gas leaks.
• The connection with rigid pipes should not cause stresses to the appliance inlet and manifold.
Before Leaving
• Check all connections for gas leaks using a soapy solution – DO NOT use a naked flame to detect leaks.
• Ignite all burners both individually and concurrently to ensure correct operation of gas valves, burners and ignition.
• Turn gas taps to low flame position and observe stability of the flame for each burner individually and concurrently.
• When satisfied with the hotplate, please instruct the user on the correction method of operation.
• If the appliance fails to operate correctly after all checks have been carried out, contact the authorised service
provider.
• A data label is located on the bottom of the appliance. In the event the data label is not visible in the installed
position, a duplicate data label is supplied to adhere in an accessible area next to the appliance.
Operations to be performed when the conducting the Gas Conversion
If the injectors are not supplied they can be obtained from the service agent.
•
Remove the gratings and the burner covers
•
Using the wrench, substitute the nozzle injectors (J) with a suitable type for the
kind of gas for which it is to be used (see injector table).
•
The burners are conceived in such a way so as not to require the regulation of
the primary air.
Installation
Содержание HGA604FKSS
Страница 4: ...Operating Instructions ...
Страница 7: ...Installation Cutout Dimensions 650mm 30mm 50mm ...