22
Step
Parts to remove
Remarks and procedures
Fasteners
10
Stop switch
Disconnect the wire and remove the stop switch from
the blower housing.
+ screwdriver
M4 x 12 mm : 2 pcs.
11
Recoil starter
Remove the recoil starter from the blower housing.
10 mm box spanner
M6 x 14 mm : 4 pcs.
12
Blower housing
Remove the blower housing from the crankcase.
10 mm box spanner
M6 x 12 mm : 3 pcs.
13
Cylinder baffle
Remove the
cylinder baffle 1 and 2
10 mm box spanner
M6 x 12 mm : 3 pcs.
CYLINDER BAFFLE 2
CYLINDER BAFFLE 1
Stop switch
Blower housing
Recoil starter