– 40 –
25) ADJUST GOVERNOR SYSTEM
(1) Push speed control lever all the way to the high
speed position and fix it by tightening nut.
(2) Check that governor lever is pulled by governor
spring and carburetor throttle valve is fully open.
(3) Turn governor shaft counterclockwise all the
way and tighten lock bolt to secure the lever on
the shaft.
26) BLOWER HOUSING
Attach blower housing to crankcase.
27) FUEL PUMP
Install fuel pump onto #2 cylinder baffle.
Connect fuel pipe between carburetor and fuel
pump.
28) AIR CLEANER
(1) Connect breather pipe to air cleaner base.
(2) Fit air cleaner base onto carburetor.
(3) Connect breather pipe to #1 cylinder head.
(4) Set air cleaner element along with urethane
foam onto base.
(5) Install air cleaner cover with knob.
GOVERNOR LEVER
GOVERNOR SHAFT
Fig. 5-50
FUEL PUMP
Fig. 5-51
AIR CLEANER BASE
Fig. 5-52