SECTION 1
8
: S
PECIFICATIONS
73 of 75
SECTION 1
8
: SPECIFICATIONS
1
8
.1 Material Specifications
1
8
.1.1 Combustion and Tubes
100 mm dia. 16 ga
u
ge heat treated
al
u
minised mild steel.
1
8
.1.2 Reflectors
NS3 H14 al
u
mini
u
m or 1.4016 2R stainless
steel (option).
1
8
.2 Heater Specifications
1
8
.2.1 Se
q
uence Controller
F
u
lly a
u
tomatic, three try, direct spark, 100% sh
u
t off
ignition flame rectification mod
u
le.
1
8
.2.2 Electrical
Rating: 230V, 50 Hz, 1 Ø, 1 A
Connection: 3 pin mo
u
lded pl
u
g
1
8
.2.3 Gas Supply
Connection: Rc1/2 (1/2" BSP int)
Nat
u
ral G20:
Minim
u
m - Inlet 15 mbar (6 in
w
g)
Maxim
u
m - Inlet 50 mbar (20 in
w
g)
Nat
u
ral G25:
Minim
u
m - Inlet 17.5 mbar (7 in
w
g)
Maxim
u
m - Inlet 50 mbar (20 in
w
g)
LP Gas (Propane or B
u
tane):
Minim
u
m - Inlet 32.5 mbar (13 in
w
g)
Maxim
u
m - Inlet 50 mbar (20 in
w
g)
1
8
.3 Ventin
g
Specifications
1
8
.3.1 Fans
BH-15, 20, 25, 30 ............. Model: Torin DSF 133-42
BH-25 EF, 30 EF, 35 EF,
BH-35, 40, 45 .................. Model: Torin DSA 524-202
BH-40 EF, 45 EF,
50 EF, BH-50 .................. Model: Magnetek JF1G
BH30DL, 40DL, BH50DL/EF,
60DL/EF, 70DL/EF ........... Model: Magnetek JF1G
M
u
ltib
u
rner
.................. Model: Airflo
w
83 BWLG
.................. Model: Airflo
w
90 BWTL
Cons
u
lt the man
u
fact
u
rer for a
v
ailability of alternate fans.
1
8
.3.2 Flue
When fitted, the fl
u
e m
u
st be 100 mm, or greater in
diameter, and m
u
st conform to National Codes. The fl
u
e
m
u
st be self s
u
pporting. Inlet m
u
st be 100 mm diameter.
M
u
ltib
u
rner - Fl
u
e m
u
st be 150 mm diameter and
w
ill be
sized to s
u
it arrangement and
w
ill connect to the fan. Fl
u
e
material m
u
st conform to National Codes. The fl
u
e m
u
st
be self s
u
pporting.
1
8
.4 Suspension Specifications
Hang heater
w
ith materials
w
ith a minim
u
m
w
orking load
of 33 kg.
1
8
.5 Controls Specifications
Time s
w
itches, thermostats, etc. can be
w
ired into the
electrical s
u
pply. External controls s
u
pplied as an
optional extra.
1
8
.6 Environment
The heater is limited to operate in an ambient
temperat
u
re range of 0° C – 32° C (32° F – 86° F)
w
ith a
maxim
u
m relati
v
e h
u
midity of 95%.
Содержание Blackheat BH15ST
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 23: ...SECTION 6 LINEAR DOUBLE LINEAR HEATER INSTALLATION 17 of 75 Figure 21 Double Linear General Assembly Overview ...
Страница 33: ...SECTION 7 U TUBE HEATER INSTALLATION 27 of 75 Figure 23 U Tube Assembly Overview mm 200 ...
Страница 55: ...SECTION 10 OPTIONAL HEATER ACCESSORIES 49 of 75 Figure 28 U Tube Angle Mounted Figure 29 Linear ...
Страница 63: ...SECTION 13 WIRING 57 of 75 13 4 Typical External Wiring Diagram Multiburner ...
Страница 64: ...BLACKHEAT INSTALLATION OPERATION AND SERVICE MANUAL 58 of 75 13 5 Internal Wiring Diagram ...
Страница 73: ...SECTION 16 TROUBLESHOOTING 67 of 75 Troubleshooting Flow Chart Linear Double Linear and U Tube ...
Страница 74: ...BLACKHEAT INSTALLATION OPERATION AND SERVICE MANUAL 68 of 75 16 2 Troubleshooting Flow Chart Multiburner ...
Страница 82: ......