SECTION 13: W
IRING
55 of 75
SECTION 13: WIRING
Connect to the electrical s
u
pply
u
sing a 3 pin pl
u
g
v
ia a
locally mo
u
nted do
u
ble pole f
u
sed s
w
itch ha
v
ing a
minim
u
m disconnection of 3 mm on each pole. This
s
w
itch sho
u
ld be f
u
sed to 3 amps. The b
u
rner is f
u
sed at
2 amps. There are no control connections in the standard
b
u
rner. Control is affected by interr
u
ption of the main
po
w
er inlet.
See Page 55, Section 13.1
through Page 57,
Section 13.4
for the external
w
iring details for the single-
b
u
rner, do
u
ble linear and m
u
ltib
u
rner heater systems.
All
w
iring m
u
st comply
w
ith c
u
rrent
w
iring reg
u
lations and
any local reg
u
lations
w
hich may apply. Al
w
ays s
w
itch off
the s
u
pply to the b
u
rner and disconnect by remo
v
ing the
pl
u
g before remo
v
ing the b
u
rner side panel.
For U-T
u
be heaters, fan
w
ill pl
u
g directly into b
u
rner pack.
For Linear and do
u
ble linear heaters, an interconnecting
cable
w
ill be req
u
ired bet
w
een the fan pl
u
g and b
u
rner
socket. This cable shall be three core, s
u
itable for c
u
rrent
load of 10A and shall be installed clear of appliance in
accordance
w
ith
Section 3
, Page 5
through Page 9
data.
The req
u
ired pl
u
g and socket for this cable are s
u
pplied
w
ith the appliance; cable is not incl
u
ded.
All electrical
w
iring m
u
st be carried o
u
t in accordance
w
ith
AS/NZS 3000-2007 as amended.
13.1 Typical External Wirin
g
Dia
g
ram (Linear or U-Tube)
DANGER
Electrical Shock Hazard
Disconnect electric before service.
Heater must be properly grounded.
Failure to follow these instructions can result
in death or electrical shock.
230
V
1 Ø
50 Hz
Burner 1
L
N
Earth
Fan 1
Earth
N
L
Burner 2
Fan 2
Burner 3
Fan 3
Controller or
Thermostat
Содержание Blackheat BH15ST
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 23: ...SECTION 6 LINEAR DOUBLE LINEAR HEATER INSTALLATION 17 of 75 Figure 21 Double Linear General Assembly Overview ...
Страница 33: ...SECTION 7 U TUBE HEATER INSTALLATION 27 of 75 Figure 23 U Tube Assembly Overview mm 200 ...
Страница 55: ...SECTION 10 OPTIONAL HEATER ACCESSORIES 49 of 75 Figure 28 U Tube Angle Mounted Figure 29 Linear ...
Страница 63: ...SECTION 13 WIRING 57 of 75 13 4 Typical External Wiring Diagram Multiburner ...
Страница 64: ...BLACKHEAT INSTALLATION OPERATION AND SERVICE MANUAL 58 of 75 13 5 Internal Wiring Diagram ...
Страница 73: ...SECTION 16 TROUBLESHOOTING 67 of 75 Troubleshooting Flow Chart Linear Double Linear and U Tube ...
Страница 74: ...BLACKHEAT INSTALLATION OPERATION AND SERVICE MANUAL 68 of 75 16 2 Troubleshooting Flow Chart Multiburner ...
Страница 82: ......
Страница 83: ......