Section A - 5
1200W MSD COLD STRIKE FOLLOWSPOTS
1119 CS & CCS
1419 CS & CCS
Rober
t Juliat r
eser
ve
the right to change or alter an
y of the items detailed on this page
, to incr
ease or impr
o
ve manuf
ac
turing
techniques without prior notic
e.
TECHNICAL FILE
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
DESCRIPTION.
A
1200W Cold strike profile.
c
Lighting unit's power cable.
Cable H07 RN-F 4G 1,5mm
2
length 3m fitted
with a 3 point + E, P17 male plug.
B
Power supply unit (P.S.U.)
Refer to sections A -10 & C - 6.
Before connecting to the mains.
- Check the power conformity; P.S.U. power 1 conform with lamp power : 1200W.
- Check the voltage conformity with the mains: 230V/50Hz or 245/50Hz or 208/60Hz.
•
Untighten the screw 3 .
•
Turn the switch 4 to select the appropriate voltage.
•
Then tighten the screw 3 .
Lighting unit / Power supply connection.
- Connect the lighting unit’s A power cable C to the P.S.U. B .
- Place the lamp into position - refer to section A - 9.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet when
the lighting unit is on.
- Never connect to a dimmable channel.
- Use only when lamp in place.
11°
9°
7°
13°
14,7°
9°
7°
11°
14,
7°
13°
1
1
1
9
c
A
230V.
50Hz
208V.
60Hz
245V.
50Hz
4
1
B
2
3
CONNECTIONS.
For 208/230/245V version.
Make sure the fan is working correctly
when switching on the unit.
Содержание 1419 CCS