robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
VALID SINCE
: 16.02.05
DocT
ech1011_BC_0205.ind
8
TECHNICAL FILE
1200W HMI FOLLOW SPOT
A405197
ATTENTION PROJECTEUR HMI - PRECAUTIONS D'UTILISATION.
WARNING! HMI SPOTLIGHT - OPERATING INSTRUCTIONS.
• Avant de mettre l'appareil en service, veuillez lire
les consignes d'utilisation.
• Intervention par technicien qualifié.
•
Read user's instructions before using this lighting unit.
•
Service only by qualified technician.
50
°
40
°
LAMPES /
LAMPS.
OSRAM : HMI 1200 GS.
PHILIPS : MSI 1200 W.
CULOT /
BASE : S Fc 15,5 - 6
180
t a = 40
°
C. t max = 150
°
C.
CONTROLE
U
L
= 100
±
10V. IP 20.
P = 1200W.
A
L
= 13,8A.
robert juliat
Made in EEC - France -
kg
=
MODELE
1011
+
Alim /
P.S.U
A 1200
2,4m
29Kg
9625658
1
5
6
9
2
3
4
7
8
10
CONTR
O
LE
P = 1440W.
A = 6A.
Cos Ø = 0,90
±
5%.
ALIMENTATION POUR LAMPE A DECHARGE
DISCHARGE LAMP P.S.U.
VERSION
IP20.
t a = 40°C. t max = 100°C.
robert juliat
Made in EEC - France -
kg
=
MODELE
1011+ = A6 1200
1011+B = A4 1200
1011+C = A4 1200C
1
5
6
2
3
4
9619027 HMI
D
- The identifi cation plate situated on the 1200W HMI Follow spot.
THE IDENTIFICATION PLATES.
- The identifi cation plate situated on the 1200W power supply unit for:
Unity used :
- Dimensions = metre (m) millimetre (mm).
- Frequency = Hertz (Hz).
- Weight
= Kilogramme (Kg).
- Power
= Watts(W).
- Intensity
= Ampere (A).
- Temperature = Degree Celsius (°C).
- Voltage
= Volts (V).
1 User's instructions,
read the previous page
attentively.
2 The brand mark, manufacturer's name and
origin of the product.
3 Control N°: Year & WeeK.
4 Conformity European.
5 Net weight without accessories.
6 Lighting unit's reference & technical characteristics :
- The type of power supply unit necessary.
- P = Maximum power authorised.
- A
L
= Max. amp intensity.
-
U
L
=Max. voltage at the lamp terminal.
- IP 20 = indoor use ONLY.
- t a = surrounging temperature.
- t max = External maximum temperature
of the unit.
7 Restrictive position use:
front view.
8 Minimum distance between a flammable
material and the lighting unit.
9 Types of admissible lamps.
10 Type of lamp base accepted.
1 Power supply description.
2 Power supply reference & technical characteristics :
- P = Maximum power authorised.
- A = Normal intensity.
- Cos Ø = dephasing between the voltage & current.
- The unit version & lamp power.
- t a = surrounging temperature.
- t max = External maximum temperature
of the unit.
- IP 20 = indoor use ONLY.
3 The brand mark, manufacturer's name and
origin of the product.
4 Control N°:-
Year, Week, unit N° & type.
5 Conformity European.
6 Net weight.
1011+, 1011+B &
1011+C
Содержание 1011+
Страница 2: ...NOTES ...