TECHNICAL FILE
1200W HMI FOLLOW SPOT
IGNITION'S TIME-DELAY - ref.: 1011
+
only.
The adjustment is effectuated at the factory;
Ignition's time-delay : 5/10 of a second ±20%.
! ATTENTION.
- It is inadvisable to adjust the time-delay without
consulting beforehand our technical services.
- The circuit board's power is NOT isolated from
the 230V network.
- Service only by qualified technician.
CHANGING THE IRIS CASSETTE.
- Unscrew the button 1 that fixes the iris cassette
to the lighting unit.
- Remove the iris cassette 2 by pulling on the handle.
- Mount the new iris cassette into place.
- Manually screw the button 1 once the iris cassette
is in place.
RJ404412-A
0,54
sec.
Lamp ON, checklight
Always adjust to
0,54 sec. (in a anti-
clockwise direction).
Time-delay circuit.
(found inside the power
supply unit, see page 37).
GOBOS CHANGER SETTING.
NOTE.
Before adjusting, put a drop of breaking
fl
uid onto the threads
of the setting screws.
INSIDE THE ZOOM.
Setting screws for gobo changer.
Adjusting stopper for positioning.
2