robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
VALID SINCE
: 16.02.05
DocT
ech1011_BC_0205.ind
12
TECHNICAL FILE
1200W HMI FOLLOW SPOT
A
B
C
D
E
e
f
g
h
CONNECTIONS.
1011+B
Lighting unit / Power supply connection.
- Connect the lamp cable C to the connector 7 of the
P.S.U. and connector e to the lighting unit.
- Connect the cable D to the connector ( d ) of the
ballast and to the connector g of the lighting unit "XLR7".
- Place the lamp into position - refer to page 14.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the the connector ( c ) "XLR4".
( For the connection configurations : refer to page 24 ).
- Connect the optional units that are possible, to connector f
( Only DATA ).
- Plug the cable 8 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the automatic breaker 3 and check that the CAD 900
protection 4 is well engaged.
- Engage the automatic breaker 2 .
- Lock the cable C into the cable lock i .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp is in place.
A 1011
+
B - Motorized shutter with CAD.
e
- EM HARTING 16 x 16A power socket.
f
- 10A. EEC - Female mains socket.
g
- EM XLR7 s DATA.
h
- EF XLR5 output DATA.
B Power supply unit.
1
- Mains checklight.
2
- 6A automatic breaker.
3
- General 16A automatic breaker (
208/245V
).
4
- 1A automatic breaker.
6
- Ventilation opening
(DON'T OBSTRUCT THE AIR GAPS).
7
- EF HARTING 16 x 16A - 2 latch connector.
8
- Mains cable 3G x 1,5 mm
2
(2,5m) + 10/16A. male plug.
9
- CAD 900 local controls.
10
- Rating plate.
11
- Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp
cable.
Cable H07 RN-F 19G1,5 mm
2
length 3m fitted
with 16 x 16A M/F HARTING connectors.
D Shutter
cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
E Analog control fader cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR4 M/F connector.
DATA
DMX 512 Line.
DATA Line.
DESCRIPTION.
Power supply unit
(P.S.U.)
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
i
Содержание 1011+