DigitalSpot 5000 DT
9
9. Rigging the fixture
Please consider the respective national norms during the installation!
Verify the truss or support will handle the combined weight of all the fixtures on the truss
Always use a secondary safety cable when mounting this fixture
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, under
high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
To ensure reliable operation of the product and to protect it from overheating, the vents must not be blocked or
covered.
Hot air is exhausted from the exhaust vent. Do not put any flammable object near the fixture, hot air is exhausted
from the air vents.
Keep the exhaust vents at least 1 m away from any objects.
Do not touch peripheral parts of the exhaust vent, especially screws, grids and metallic parts. These areas
will become hot while the fixture is being used.
Do not put anything on the fixture. Objects put on the fixture will not only get damaged but also may cause fire
hazard by heat.
Allow the fixture to cool for 20 minutes before handling.
The fixture should be installed out of the reach of people.
We recommend avoiding dusty/smoky environments when operating the fixture. Usage in these environments
may cause a poor image quality. When using the fixture under dusty or smoky conditions,dust may accumulate
on a lens, liquid crystal panels, or optical elements inside the projector. Such condition may degrade the quality
of the projected image.
MPORTANT! Overhead rigging requires extensive experience, including calculation of working load limits,
installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack
these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger.
Improper installation can result in bodily injury and or damage to property.
The fixture must never be fixed swinging freely in the room.
Use 2 appropriate clamps to rig the fixture on a truss.
Make sure that the device is fixed properly!
Ensure that the structure (truss) to which you are attaching
the fixtures is secure.
For overhead use, always install a safety cable that can hold at least 10 times the weight of the fixture. You must
only use safety cables with screw-on carbines. Pull the safety cable through the two apertures on the bottom of
the base and over the trussing system etc. Insert the end in the carbine and tighten the fixation screw.
A pair of the Omega holders can be placed in 4 positions on the bottom of the base. Use 2 clamps (not supplied)
with screws M12.