![Robe Color Wash 700E AT Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/robe/color-wash-700e-at/color-wash-700e-at_user-manual_1468947031.webp)
3
Supply Frequency Error
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices.
In these cases the message does not affect the fixture operating!
Temper.Sensor Error
The message informs you that the communication betwen the head and the main board in the fixture base was
cut off (or the head temperature sensor is defective) and the lamp was automatically switched off.
Power down mode
This message will appear if the fixture is switched to the "Power down mode" (e.g. fixture head is overhea
-
ted).
The following error messages are separated into groups:
xxxx xxxx Error 1
(e.g.
Colour Wheel 1 Error 1
)
xxxx xxxx Error 2
(e.g.Colour Wheel 1 Error 2 )
There are some possible reasons of faults:
Message
Characteristic fault
xxxx xxxx Error 1
Magnetic sensor is permanently On (e.g. leading wire is short-
circulated,defective stepping motor, defective control circuit on the
PCB)
xxxx xxxx Error 1/xxxx xxxx Error 2
Magnetic sensor is permanently Off(e.g.leading wire is disconnected,
defective magnetic sensor,missing magnet),defective stepping motor
Colour Wheel Error 1 (Colour Wheel Error 2 )
The messsages will appear after the reset of the colour wheel if this wheel is not located in the default positi-
on.
Effect Wheel Error 1 (Effect Wheel Error 2 )
The messages will appear after the reset of the effect wheel if this wheel is not located in the default position.
Effect Index. Error 1 (Effect Index. Error 2 )
The messages will appear after the reset of the effect wheel if the beam shaper wheel ls are not located in the
default position.
Optical Zoom Error 1 (Optical Zoom Error 2 )
The messsages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Crop Zoom Error 1 (Crop Zoom Error 2 )
The messsages will appear after the reset of the zoom module if the additional iris not located in the default
position.
Pan Error 1 (Pan Error 2)
The messages will appear after the reset of the yoke if the yoke is not located in the default position.
Tilt Error 1 (Tilt Error 2)
The messages will appear after the reset of the head if the head is not located in the default position.
Cyan Lamella Error 1 (Cyan Lamella Error 2 )
The messsages will appear after the reset of the cyan flag if the flag is not located in the default position.
Magenta Lamella Error 1 (Magenta Lamella Error 2 )
The messsages will appear after the reset of the magenta flags if the flag is not located in the default positi
-
on.
Yellow Lamella Error 1 (Yelow Lamella Error 2 )
The messsages will appear after the reset of the yellow flags if the flag is not located in the default position.
CTO Lamella Error 1 (CTO Lamella Error 2 )
The messsages will appear after the reset of the CTO flag if the flag is not located in the default position.