6
10. Error and information messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp
is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The ClubSpot
300 will store this information and automatically ignite the lamp when the 5 minutes period has expired.
Caution:
The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off (only if the lamp
was turned Off and On within 5 minutes,the message "
HEAt
" will appear).
LA.Er.
The ignition of the lamp is seven times unsuccessful (the "
HEAt
" message appeared six times before), and the
display shows
"
LA.Er
"
, meaning that the lamp could be damaged or even missed, the fixture is overheated (this
can occur if the ambient temperature is 40° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was
not caused by the lamp.
Caution:
The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off.
Mb.Er.
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
Co.Er.
(color wheel error)
This messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The color-
wheel is not located in the default position after the reset.
r.GEr.
(rotating gobo wheel error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed
or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo
wheel is not located in the default position after the reset.
iGEr.
(rotating gobo indexing error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed
or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo
is not located in the default position after the reset.
Ft.Er.
This error message informs you that the fixture was overheated (occured if the ambient temperature is 40° C
or more) and that the relay switched off the lamp.
Fr.Er.
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices.
In these cases the message does not affect the fixture operating!
Sn.Er.
This message appears if the lamp light sensor is failed.
PoEr
This message will appear if the fixture was shortly disconnect from the main.
PA.Er.
(Pan-yoke movement error)
This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuits malfunction
(sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
yoke is not located in the default position after the reset.
ti.Er.
(TILT-head movement error)
This message will appear after the reset of the fixture if the head’s magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
head is not located in the default position after the reset.
MA.Er.
(Master error)
The message informs you that the fixture was addressed as a master and DMX signal is connected to its
input.Disconnect the DMX controller from fixture's input and address the fixture as the master again.