CitySource 96 (RGBW)
22
SUPPORTED_PARAMETERS
*
SOFTWARE_VERSION_LABEL
*
DMX_START_ADDRESS
*
*
IDENTIFY_DEVICE
*
*
DEVICE_MODEL_DESCRIPTION
*
MANUFACTURER_LABEL
*
DEVICE_LABEL
*
*
SENSOR_DEFINITION
*
SENSOR_VALUE
*
DISPLAY_LEVEL
*
*
DEVICE_RESET
*
DMX_PERSONALITY
*
*
DMX_PERSONALITY_DESCRIPTION
*
STATUS_MESSAGES
*
STATUS_ID_DESCRIPTION
*
DEVICE_HOURS
*
8. Error and information messages
t.M.Er
.
(Temperature measuring error)
The message informs you that the LED module temperature sensor is defective.
MA.Er
.
(Master error)
The fixture is set as a master and DMX console is connected to the fixture.
9. Wireless DMX operation
The wireless version of the CitySource 96 is equipped with the Lumen Radio CRMX module and antenna for
receiving DMX signal. CRMX module operates on the 2.4 GHz band.
To link the fixture with DMX transmitter.
The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter .
After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item “
v.InF
“ (SPEC-->vAdI.--> v.InF.)
To unlink the fixture from DMX transmitter.
The fixture can be unlinked from receiver via the menu item “
v.UnL
.“ (SPEC-->vAdI.--> v.UnL.).