Table of contents
Power Peak® A4 EQ-LCD
No.
8559 / 8560
6
NiMH charging mode
When charging NiMH batteries, the charger is
switched off using the Delta Peak Method.
Battery status
Status LED
1
No charging
LED and battery type flash
green at 0.5 sec intervals
2
Charging started
LED constantly lights green
3
Battery charged
Beeper sounds for 15 sec
LED lights orange
8. Equalizing Without Charging
1. Use the voltage sensor lead to connect a
lithium battery
to the charger via the voltage
sensor connection.
2. Ensure correct polarity and position when
connecting. The black wire of the sensor lead
must be aligned with the arrow mark on the
charger casing.
3. Ensuring correct polarity, now connect the
main power cables of the battery to the con-
nection at the charger (red = +/black = -).
4.
Briefly
press the Start button.
5. The battery voltage is shown in the display
during the charging process.
6. Briefly press the Start button again to stop the
equalizing process.
The equalizer LEDs indicate the status of the
connected cells.
Constantly flashing or lit LEDs indicate that the
cells are being balanced.
The LEDs only flashing sporadically or off indi-
cate that the battery is balanced and is ready for
use.
Battery status
Status LED
1
Equalizing phase
LED flashes orange
at 0.5 sec intervals
2
End of equalizing
LED flashes orange with
number of cells, beeper
sounds for 15 sec
9. Fault Signalling
A fault is indicated by the status LED flashing
in the corresponding LED flash sequence, (----)
flashing in the LC display and the beeper sound-
ing at 0.5 second intervals.
After eliminating the cause of fault, the fault code
memory is reset by pressing the Start button.
Cause of fault
LED
flash sequence
1
Input voltage is lower than
11 or higher than 15 Volt
1
2
Battery connected with
reversed polarity
2
3
Main power supply cable dis-
connected during charging
3
4
Sensor lead disconnected
during charging
5
5
Fault in power circuit
6
10. Specification – Charger
Input:
11...15 V DC /
110-230 V AC
Number of cells:
1...4 LiPo cells
4 ... 8 NiMH cells
Charging current:
0.3 ... 3 A
Charging power:
max. 30 W
Charge termination:
CC-CV/Delta Peak
Dimensions:
120 x 65 x 24 mm
Protective functions
- Input side:
- Output side:
Polarity reversal protection
Polarity reversal and
short-circuit protection
11. Specification – Power Supply Unit
(No.8560)
Input:
110-230 V AC/50 Hz
Charge current
max. 4 A
Output:
12 V DC
Dimensions:
111 x 47 x 33 mm
Protective functions
- Output side:
Polarity reversal
protection