background image

 

OM2750.docx 

 

Donning Instructions 

 

It is important that your PFD is properly adjusted to fit you. An incorrect fit or improper fastening of the belt or 
attachments may impede its performance. 

The waist belt fastening system is sewn on and it utilises a quick release buckle for fastening and has an 
adjustable mechanism to fit an average person properly.  

 

Figure 7

 

 Put the Inflatable PFD on just like a jacket as depicted by Figure 7 and fasten the front buckle. Adjust the waist belt 
using the side release buckle on the belt and secure the belt’s loose end in the belt loop.  

This is a constant wear PFD and it is recommended that you are familiar with the donning instructions .It is very 
important that you wear your Inflatable PFD over a clothing. 

 

If crotch strops are attached pull these through your legs in a crossover style and attached to the buckles at the 
base of the PFD lobes. 

 

CAUTION

Do not wear your Inflatable PFDs under clothing or harnesses as the inflation could be restricted 
and affects its performance and you may also injure yourself 

 

Now that you are happy that everything is in place including familiarisation in donning, it is highly 
recommended that you practice using your inflatable PFD & test it in safe shallow water. 

 

 

 

 

 

Содержание SMA2750

Страница 1: ...S SM S OWN SMA2751 MA2752 SMA2750 NERS MA 1 MANU AUTO IN 0 NUAL UAL INFL NFLATIO LATION ON...

Страница 2: ...nflatable PFD 9 Re arming Your PFD after Manual Inflation SMA2751 10 Re arming your after inflation PFD as Manual Automatic Backup SMA2752 10 Note on the Automatic PFD 10 ROUTINE INSPECTIONS OF YOUR P...

Страница 3: ...ill provide a minimum buoyant force of 28 3kg 278 Newtons when it is fully inflated SMA2750 is very light weight without the harness and other attachments However the Essential Services model such as...

Страница 4: ...m see fig 1 The valise also houses the adjustable waist belt system but the latter can be detached from the bladder Like the bladder there are donning operating instructions markings It also has a mar...

Страница 5: ...750 this can be overcome by topping up the pressure of the bladder through the oral tube inflation system Another characteristic of carbon dioxide gas is that under colder conditions it will not expan...

Страница 6: ...orated 4 Check for inflation leakage Gently uncap the dust cap of the oral tube If provided Inflate the buoyancy bladder by mouth until it is firm and leave it overnight If it is airtight it should re...

Страница 7: ...Figur Dust ca stowed O re 2 p in the position OM2750 doc Figure 1 D d Figure 4 cx F ust cap in t deflate posit Figure 3 he tion 5...

Страница 8: ...6 OM2750 docx Figure 5 Figure 6...

Страница 9: ...belt and secure the belt s loose end in the belt loop This is a constant wear PFD and it is recommended that you are familiar with the donning instructions It is very important that you wear your Infl...

Страница 10: ...r is immersed in water The water sensitive paper element or bobbin will disintegrate This will trigger a spring loaded plunger to puncture the CO2 cylinder head Thus allowing the escaping gas to infla...

Страница 11: ...eflate your PFD in accordance to the instructions given below Allow your PFD to dry thoroughly in dry but well ventilated area away from direct sunlight Rearm your PFD according to your model Repacked...

Страница 12: ...O2 cylinder and discard it Unscrew and remove the auto cartridge Fig 6 Using Roaring Forties kit KIT400 60 install a new auto cartridge with the green indicator at base and gently hand tighten to the...

Страница 13: ...sure all air is extracted from the bladder and that the bladder is tied to the back of the valise The tie is threaded through the 2 neck and 1 head retaining loops 2 Fold the bottom lobes of the bladd...

Страница 14: ...6 Fold the collar portion underneath by another third 7 Fold the collar portion over another third 8 Fold the collar retaining webbing inside the valise ensure it is place in the centre of the jacket...

Страница 15: ...eplace with an unused 60 gram CO2 cylinder The cylinder for the SMA2751 is contained in accessory pack KIT160 60 The cylinder for the SMA2752 is contained in accessory pack KIT400 60 iii Check the man...

Страница 16: ...flatable PFD using a plastic coat hanger Ensure the inflator is thoroughly dry before installing the automatic cartridge Make sure to re install an unused CO2 cylinder see Re arming your PFD SMA2752 a...

Отзывы: