15
R
O
-M
A
N
®
Conditions for Operation
Source Water: Community / Private / Non-Chlorinated / Chlorinated providing the carbon filter is utilised
and replaced every 6 months or every the recommended output, whichever comes first.
SYSTEM PRESSURE
(PRE-FILTRATION)
0 – 80 PSI
MEMBRANE
PRESSURE RANGE
40 – 125 PSI
TEMPERATURE
4º-38º C (40º-100º F)
PH RANGE
3.0-13.0
MAXIMUM SUPPLY
TDS LEVEL
1500 MG/L
TURBIDITY
<1.0 NET TURBIDITY (NTU)
HARDNESS (CACO.)
<350 MG/L (<20 GPG)
IRON (FE)
<0.1 MG/L
MANGANESE (MN)
<0.05 MG/L
HYDROGEN SULFIDE (H2S)
0.00 MG/L
CHLORINE (CL2)
0.00 MG/L
Nominal Rejection Characteristics
Thin Film Composite Reverse Osmosis Membranes:
Calcium
93-99%
Sodium
92-98%
Magnesium
93-98%
Potassium
92-96%
Manganese
96-98%
Iron
96-98%
Aluminium
96-98%
Copper
96-99%
Nickel
96-99%
Cadmium
93-97%
Silver
93-96%
Zinc
96-98%
Mercury
94-97%
Hardness Ca&Mg
93-97%
Radioactivity
93-97%
Chloride
92-98%
Ion
92-98%
Bromide
90-95%
Phosphate
95-98%
Cyanide
90-97%
Sulphate
96-99%
Thiosulfate
96-98%
Silicate
92-95%
Silica
90-98%
Nitrate
90-95%
Boron
50-70%
Borate
30-50%
Fluoride
92-95%
Polyphosphate
96-98%
Orthophosphate
96-98%
Chromate
85-95%
Bacteria
99+%
Lead
95-98%
Arsenic