6
Program settings:
CH1 to CH3 three program settings
Set as follows:
At the same time, hold down the SET button on the screen and the green button on the
handle for two seconds. After the indicator is released, the blue number 00 will start
flashing.
This figure is used to calibrate the temperature. Without adjustment, CH1 and the
temperature will start to flash when you press the SET button. You can use the and
symbols below the CH to adjust the desired temperature. The adjustable temperature is
100°C-500°C.
Press the SET key again when adjusting to the desired temperature. The digits will start
to flash and the air volume can be adjusted from 0-200.
Press the SET key again to adjust the temperature of CH2. Then press SET to adjust the
flow of CH2. Press SET to adjust the temperature of CH3. Press SET again to adjust the
flow of CH3. Press SET again to adjust the conversion between °C and °F. After all the
programs have been adjusted, press ENTER again to complete all program settings.
Note: The air force is not adjustable to zero, the higher the temperature, the air volume
should remain high. To protect the life of the heating core.
Energy safe Function
Long press the green button for three seconds, the host enters the dormant state. At
this time, the air volume is fully on, the temperature of the heater core is quickly cooled
to below 100°C, the display screen shows the moon as below :-
The fan stops running, and it enters the dormant state. To restart, remove press again.
Press the button to start the host.
If the air gun is placed on the shelf, the hibernation function will also be activated. Pick up
the air gun host from the rack and start it instantly.
Displays the ––– symbol while sleeping
7
Nozzles replacement
Use a U-shaped piece on the front of the rack to remove the desoldering head, but use a
needle nose pliers when installing a new desoldering head
Factory setting:
CH1. Temperature 150°C Air volume 100, CH2. Temperature 300°C Air volume 120, CH3.
Temperature 450°C Air volume 180
Front Panel
No.
1
2
3
4
FUNCTION
Heating
Cooling
Standby
Set Temperature
DESCRIPTION
When lit, it shows that the element is heating up,
temperature increase. When it flashes, it shows
that the temperature is being maintained at the
set temperature.
When it appears on screen, it shows that they
element is cooling down, decreasing
temperature.
When it appears on screen it shows that they
element is in standby mode, and the heat gun is at
or near room temperature. Press White
button – temperature will rapidly increase to
resume soldering.
Use the arrow buttons to set the temperature to
a desired level, which is displayed here. CH0 is the
default operating mode, 100 – 500 °C
Содержание 560-00159