10
DO NOT WORK ON LIVE CIRCUITS.
Before working on any mains powered equipment,
make sure thatit is turned off, and the mains plug is removed from the power point.
Product Specification
Model
Power Voltage
Power Consumption (Max)
Pump
Temperature Range
Fuse (Fast Type)
RND 560-00159
100-120Vac 60Hz/ 220-240Vac 50Hz
1300W
Diaphragm 220V
100
0C
-500
0C
Fast Type (10A)
OPERATING PRECAUTIONS
1.
Make sure both heater and nozzle are cool before attaching the nozzle.
2.
Caution High Temperature Operation
Do not use the LF- 861D near ignitable gases, or other inflammable materials.
Both nozzle and hot air are extremely hot and can cause burns. Never touch the
nozzle and heater assembly or allow the hot air to blow against your skin.
Initially, the iron may emit white smoke, but this will soon dissipate.
3.
Be sure to cool the unit after using. While the power switch off, the unit will
automatically blow cooling air through the pipe for a short period of time. Do not
disconnect the plug during this cooling process.
4.
Do not disassemble the pump. If the pump or other critical internal components
become faulty, discontinue its use immediately. Please return to your vendor or its
authorized repairers for proper servicing.
5.
Disconnect the plug while the unit is not in use.
When the power cord is connected into the power supply, the unit has a little flow
of electricity; even the Power Switch is in off position. So when you don’t use the
unit for a longer period of time, disconnect the plug.
11
IMPORTANT:
Do not force the nozzle or pull on the edge of the nozzle with pliers. Also,
do not tighten the set-screw too tightly.
Suitable for desoldering of SMD components such as SOIC, CHIP, QFP, PLCC, BGA etc.
QFP De-soldering
1.
Melt the solder: Hold the iron so that the nozzle is located directly over, but not
touching the IC and allow the hot air to melt the solder. Be careful not to touch
the leads of the IC with the nozzle.
2.
Remove the IC: Once the solder has melted, remove the IC by lifting the pliers.
3.
Turn the power switch off: After the power switch is off, an automatic blowing
function begins sending cool air through the pipe in order to cool both the
heating element and the handle. So do not disconnect the plug during this
cooling process.
4.
In case you don’t use the unit for a long time, disconnect the plug.
Note: After the power switch off about one minute later, the temperature will fall
down to 75
0C (1670C) and power automatically shut off.
5.
Remove any remaining solder: After removing the IC, cleaning the remaining
solder chips with a wick or desoldering tool.
Note: For SOP, PLCC etc. would recommend by using tweezers iron to desolder.