4
Warning
•
We do not recommend continuously using at low air flow and high temperature.
Let the heating element be cooler after using a maximum 20 minutes. Ensure that it
is placed back on its cooling stand to cool down between rework operations. Also, do
not switch the hand tool on while it is in the cooling stand.
Fail to comply with the
instructions may result in damage to the hand tool.
•
Do not aim the hot air at your eyes.
Do not allow the hot air from the hand tool to aim
the eyes as serious eye damage may occur.
•
The hot air pencil can produce a lot of heat.
Do not allow the heater and the nozzle to
contact exposed skin as burning may occur. To eliminate the possibility of burns, allow
time for the equipment to cool before commencing maintenance.
•
Death or serious injury may result from electric shock.
It is therefore essential to
isolate the equipment from the mains before commencing repairs.
•
Keep the hot air away from the body, clothes and flammable material when in
operation.
The nozzle metal is in a high temperature status, do not touch the nozzle!
Always replace the hand tool to its original holder when not being use. The nozzle and
the heating element will still be hot after being switched off. Ensure that you
do not touch them.
•
Do not block the air outlet in full area of the nozzle, or it may cause the heat
reflection and damage the heating element.
•
Do not leave the machine.
Turn off the machine and unplug the power cord when you
are not using it and put the hot air handle into the holder of the machine. The nozzle
will still be hot after being switched off for some time. Ensure that you do not touch
the nozzle.
•
Do not use if damaged:
If the pump doesn’t work or the rework station becomes
faulty, discontinue using immediately. To comply with safety standards, the pump
or other part must only be replaced by authorized technicians as special purpose
tools are required. Only the technician is permitted undertake repairs. Use the original
replacement part only.
•
Remember unplug in the power cord:
The station must be switched off and the
power cord must be unplugged before replacing the fuse in AC socket in rear side of
the machine.
5
Product Features
• Intelligent chip microcomputer control design, double LCD display operated by pressing
keys, convenient and comfortable operation.
• Temperature and air blow by digital display readout, easy to read.
• With the high power heating element, heats up quickly, momentary power can
reach 1300W.
• Temperature adjust, suitable for removing QFP, SOP, PLCC or SOJ chips etc.,
built in static free circuit design is safe for the sensitive elements like CMOS ICs.
• Auto-cooling design: When the heat gun is placed on the stand, power off. The
cooling system will begin to work automatically, temperature falls down to to
protect the heating element from burning.
• Heating element auto-protecting function: When heating element reaches a high
temperature can be protected automatically. This prolongs the life of the device
Operating Procedures
Start
Insert the power cable connector into the AC connector on the back of the machine and
then plug the power cable into the power socket.
Turn on the power switch at the back of the machine.
The start function is performed by the CH0 program. This program is used during power
on, and the temperature and air volume can be adjusted. If you want to use the CH1-CH3
program, press the green button on the handle to start the setting of CH1 to CH3. The
program will be on CH1. - Cycle between CH3.