10
Specifications
General Specifications
LCD display digits : 4000 counts digit large scale LCD readout.
Measuring rate : 3 times / sec.
Polarity Indication : Automatic, positive implied,
Overrange display : “OL” or “-OL”
Unit symbol indication.
Automatic power off time : Approximately 20 minutes after power on.
Low battery indicator : < is displayed. Power requirement : 1.5V x 2 batteries
Battery life : 50 hours (GPA76P)
Environmental Conditions
Indoor Use:
Calibration: One year calibration cycle.
Operating temperature:
0°C ~ 30°C (
<
80% RH)
30°C ~ 40°C (<75% RH)
40°C ~ 50°C (<45%RH)
Storage temperature: -20 to +60°C, 0 to 80% RH (batteries not fitted).
Temperature coefficient Add 0.2 x (Specified accuracy) / °C, < 18°C, > 28°C .
Shock vibration: Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g maximum).
Drop Protection: 4 feet drop to hardwood on concrete floor.
Overvoltage category: IEC 61010-1 300V CAT.III. , 600V CAT.II.
Storage temperature: -20 to +60°C, 0 to 80% RH (batteries not fitted).
Temperature coefficient Add 0.2 x (Specified accuracy) / °C, < 18°C, > 28°C .
Shock vibration: Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g maximum).
Drop Protection: 4 feet drop to hardwood on concrete floor.
Overvoltage category: IEC 61010-1 300V CAT.III. , 600V CAT.II.
Содержание 355-00001
Страница 18: ...18 Auto Bereich Manueller Bereich Funktion ausw hlen Dr cken Sie die Taste SELECT um die Funktion auszuw hlen...
Страница 35: ...35 Byte av batteri Montering av b rv ska Se f ljande bild f r att byta ut batterier 1 1 2 2...
Страница 41: ...Distrelec Group AG Grabenstrasse 6 CH 8606 N nikon...