5.5.6. Code C006 Sensor linkage
Objective:
Linking of the two previously activated sensor inputs
Select code
Set code
Code C006
You can activate only one of the eight sensor links at a time
AND logic with blowing-off
the exit tracks
I = active
0 = not active
AND logic with blowing-off
the exit tracks
I = active
0 = not active
OR logic
I = active
0 = not active
Min/Max logic
I = active
0 = not active
AND / S2 logic
I = active
0 = not active
Level check with external
controller
I = active
0 = not active
Level check indicator light
I = active
0 = not active
Individual link
I = active
0 = not active
Use the following link to set priority of the channels.
Channel 2 follows Channel 1
I = active
0 = not active
(both chan-
nels operate independently)
Return
Save and return to
main menu
Brief description of individual links
AND logic of the sensor inputs with blowing-off the exit track.
Example:
Application: Twin-track feeders with accumulation checker.
Solution: Track 1 (sensor 1) full = Blow-off track 1 (relay K1)
Track 2 still clear
Track 2 (sensor 2) full = Blow-off track 2 (relay K2)
Track 1 still clear
Track 1 + Track 2 full = Bowl feeder (channel 1) Stop about 4 sec. later blowing air
stop
AND logic of the two sensor inputs without blowing-off the exit track.
The bowl feeder (channel 1) stops when both sensors are operated. Orienting air can be switched off
with delay (4 sec.) via relay K2.
AND / S2 logic
The bowl feeder (channel 1) stops when both sensors are operated. It starts when sensor 2 is cleared
again. Orienting air can be switched off with delay via relay K2.
OR logic of the two sensor inputs.
Bowl feeder (channel 1) stops when one of the two sensors is operated. Orienting air can be switched
off with delay (4 sec.) via relay K2.
Min/Max logic of the two sensor inputs.
The bowl feeder stops when both sensors are operated. The vibratory feeder (channel 1) will re-start
only after both sensors are cleared again.
Relay K1 operates on stopping of bowl feeder. Relay K2 operates 4 sec. later
(stopping the blowing air)
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE