On the device, the characteristics and state of the signal at either input can be inspected in the
The presence or loss of a signal at either port is indicated on the standby screen if
• the input port is selected as
clock master
, or
• its audio channels are routed in the
OUTPUT
section.
When using the web remote, the characteristics and state of the signal at either input can be inspected in
the
3.14. Network Connection
On the rear of the M-32 DA Pro, an RJ45 connector labeled
NETWORK
provides a connection to ethernet.
Two link speeds are supported:
100 Mb/s
and
1 Gb/s
.
A green LED (left) signals a successful link. A yellow LED (right) signals network traffic (blinking).
Both straight and crossover cables can be used (
Auto MDI-X
). Cable lengths of up to 100m are supported
when using Cat 5e or higher classification.
The network port is used to send and receive:
• up to
eight AVB audio streams
when connected to AVB switches and endpoints,
• remote status/control with
AVDECC
, and
• remote status/control with
HTTP
over IP routed networks.
RME M-32 DA Pro User’s Guide
3.14. Network Connection |
12