43
Section 4 - I
n R
oof Fr
ame I
nstal
lation
Mounting Top Angled Timber Wedge
Place top timber wedge (9) under each collector, align them and secure each with 2 screws 5x110
(24). Connect collector connections as shown in the collector installation manual. Make sure to do a
quick A = B measurements on the panels to ensure they are square.
NOTE:
Pressure test the panels and insert temperature sensor into R/H panel. The panels should
be pressure tested to 6.5 bar using either compressed air, or glycol, DO NOT USE WATER. If using
glycol cover the panels for the duration of the test.
9
24
A
B