Connection of the supply voltage
Figure 11: Terminals for connecting the supply voltage (blue border)
Connection of the supply voltage
Terminal designation
Description
16 PE
Grounding
17 PE
Grounding
18 L (power in)
Supply voltage between L and N
19 N (power in)
Output terminals switched via the unit switch
Terminal designation
Description
1 L power out
Switched supply voltage between L and N
2 L power out
3 N power out
4 N power out
Voltage
The unit switch does not disconnect the terminals from the power supply.
Before opening the housing, disconnect the unit from the power supply and
secure it against unintentional reconnection.
The installation of a suitable electrical disconnecting device is the
responsibility of the system operator.
Voltage
The maximum connected load of all consumers
must not exceed 250 VA / 1 A.
Voltage
The protective earth conductor must be connected.
Electrical installation