![Rlide R2 PRO Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/rlide/r2-pro/r2-pro_manual_1467161142.webp)
140
b.
In Adjustment press “2. Collimation”.
[2]
Adjustments
1.VO Adjustments
2.Collimation
3.Inst.Constant
4.VADJ Set
c.
In Face I precisely collimate the target,
and press [OK].
Collimate the
target
[OK]
Collimation
HA#
24
°
15’00”
OK
d.
The System indicates “Turn to F2”.
Rotate the telescope, and collimate the
same target precisely in Face,
press
[OK].
Sight the target
in reverse
position
[OK]
Collimation
HA#
204
°
15’22”
OK
e.
After setting, the screen displays “set”
,
and returns to Adjustment menu
automatically.
Adjustments
1.VO Adjustments
2.Collimation
3.Inst.Constant
4.VADJ Set
B. Optics Adjustment (professional maintenance man only)
1. Use the tangent screw to adjust the horizontal angle to the right reading which has been eliminated C,
R+C=190°13′40″
-
15″=190°13′25″
2. Take off the cover of the reticle between the eyepiece and focusing screw. Adjust the left and right
adjusting screws by loosening one and tightening the other. Move the reticle to sight object A exactly.
3. Repeat inspection and adjustment until
|
2C
|<
20".
4. Replace the cover of the reticle.
Note: After adjustment, need to check the photoelectricity coaxiality.