5.
Establishing Connection to Device
General Connection
To initially connect to the RLH Smart Relay Output you must access the device by its default IP address as
listed below:
Default Settings
!
In most cases you will need to assign a temporary static IP to your workstation to initially access the RLH Smart
Relay Output web page. The assigned temporary address should be within the same subnet as the default
address.
Example Client Device Address:
• IP: 192.168.2.10
• Subnet: 255.255.255.0
Now access the device via: http://192.168.2.17
Assigning a Static IP Address
Steps for Window XP
First:
Go to windows XP control panel and select
Network and Internet Connections
.
!
IP Address: 192.168.2.17
Subnet: 255.255.255.0
Username: admin
Password: admin
Default IP Address
Default Username/Password
Establishing Connection to Device
12