Using the Single Module Data Viewer Program • 80
appear showing the selected printer and confirming if you want to print. Verify
that the selected printer is correct and click
OK
.
8. To print the complete results, pass/fail and gas readings, of one of the files in
the upper right part of the data view window, click on one of the files to select it
and then click the print button that appears above the file details in the lower
right. A dialog box will appear showing the selected printer and confirming if
you want to print. Verify that the selected printer is correct and click
OK
.
9. To save files as they appear in the upper right part of the data view window,
click the
Save To File
button to the right of the print button in the upper left
corner of the window. The
Save To File
button has a floppy disk icon in it. A
“Save As” dialog box will appear for you to specify the filename, file location,
and file type. Select the
Text files (*.csv)
choice to save the information as a
comma separated value file that may be opened with a spreadsheet program
such as Microsoft Excel.
10. To save files to the clipboard as they appear in the upper right part of the data
view window, click the
Copy To Clipboard
button. The
Copy To Clipboard
button has a clipboard icon in it. The file will be saved to the clipboard. It can
then be pasted into a document by using the Paste command in an
application.
Deleting Data
You can delete an instrument, bump test data, or calibration data in the data view
window. The delete function is password protected to avoid accidental deletion of
instruments or data. To delete an instrument or data, perform the following:
1. Find the item you wish to delete and right click it. A window will appear that
says “Delete(D) Change Password(C)”.
2. Click on “Delete(D)”. A password entry window will appear.
3. Enter the password and click
OK
. The factory set password is “ABCDE” and is
case sensitive. A confirmation window will appear.
4. Click
OK
to complete the deletion of the selected item.
Changing the Password
The factory password is “ABCDE” and is case sensitive. You can change the
password in the data view window. To change the password perform the following:
1. Right click in the upper right or upper left part of the data view window. A
window will appear that says “Delete(D) Change Password(C)”.
2. Click on “Change Password(C)”. A window will appear prompting you for the
current password.
3. Enter the current password and click the
Current Password
button. A window
will appear prompting you for the new password.
4. Enter the new password and click the
New Password
button. A confirmation