Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
284
Address Identifier
Description
Address Identifier
Description
A0
XS
CT ratio
C8
P7
Proportional band limiter (low) [heat-side]
A1
ZF
CT assignment
C9
I6
Integral time limiter (high) [heat-side]
A2
ND
Heater break alarm (HBA) type
CA
I7
Integral time limiter (low) [heat-side]
A3
DH
Number of heater break alarm (HBA)
delay times
CB
D6
Derivative time limiter (high) [heat-side]
A4
XN
Hot/Cold start
CC
D7
Derivative time limiter (low) [heat-side]
A5
SX
Start determination point
CD
P8
Proportional band limiter (high) [cool-side]
A6
XL
SV tracking
CE
P9
Proportional band limiter (high) [cool-side]
A7
OT
MV transfer function
CF
I8
Integral time limiter (high) [cool-side]
A8
XE
Control action
D0
I9
Integral time limiter (low) [cool-side]
A9
PK
Integral/derivative time decimal point
position
D1
D8
Derivative time limiter (high) [cool-side]
AA
KA
Derivative action
D2
D9
Derivative time limiter (low) [cool-side]
AB
KB
Undershoot suppression factor
D3
V2
Open/Close output neutral zone
AC
DG
Derivative gain
D4
SY
Action at feedback resistance (FBR)
input error
AD
IV
ON/OFF action differential gap (upper)
D5
FV
Feedback adjustment
AE
IW
ON/OFF action differential gap (lower)
D6
TN
Control motor time
AF
WH
Action (high) at input error
D7
OI
Integrated output limiter
B0
WL
Action (low) at input error
D8
VS
Valve action at STOP
B1
OE
Manipulated output value at input error
D9
KI
ST proportional band adjusting factor
B2
OF
Manipulated output value at STOP mode
[heat-side]
DA
KJ
ST integral time adjusting factor
B3
OG
Manipulated output value at STOP mode
[cool-side]
DB
KK
ST derivative time adjusting factor
B4
PH
Output change rate limiter (up) [heat-side]
DC
SU
ST start condition
B5
PL
Output change rate limiter (down) [heat-side]
DD
Y7
Automatic temperature rise group
B6
OH
Output limiter (high) [heat-side]
DE
RT
Automatic temperature rise dead time
B7
OL
Output limiter (low) [heat-side]
DF
R2
Automatic temperature rise gradient data
B8
PX
Output change rate limiter (up) [cool-side]
E0
NS
EDS transfer time decimal point position
B9
PY
Output change rate limiter (down) [cool-side]
E1
NV
Output average processing time for EDS
BA
OX
Output limiter (high) [cool-side]
E2
NW
Responsive action trigger point for EDS
BB
OY
Output limiter (low) [cool-side]
E3
HU
Setting change rate limiter unit time
BC
GB
AT bias
E4
RU
Soak time unit
BD
G3
AT cycles
E5
SH
Setting limiter (high)
BE
OP
Output value with AT turned on
E6
SL
Setting limiter (low)
BF
OQ
Output value with AT turned off
E7
TS
PV transfer function
C0
GH
AT differential gap time
E8
EA
Operation mode assignment 1 (Logic output
selection function) Logic output 1 to 4
C1
KC
Proportional band adjusting factor [heat-side]
E9
EB
Operation mode assignment 2 (Logic output
selection function) Logic output 5 to 8
C2
KD
Integral time adjusting factor [heat-side]
EA
KM
SV select function
C3
KE
Derivative time adjusting factor [heat-side]
EB
MC
Remote SV function master channel
module address
C4
KF
Proportional band adjusting factor [cool-side]
EC
MN
Remote SV function master channel
selection
C5
KG
Integral time adjusting factor [cool-side]
ED
DY
Output distribution master channel mod-
ule address
C6
KH
Derivative time adjusting factor [cool-side]
EE
DZ
Output distribution master channel selec-
tion
C7
P6
Proportional band limiter (high) [heat-side]
EF
RL
Address of interacting modules