Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
275
Address Identifier
Description
Address Identifier
Description
64
HA
Event 1 differential gap
93
OL
Output limiter (low) [heat-side]
65
TD
Event 1 delay timer
94
PX
Output change rate limiter (up) [cool-side]
66
OA
Force ON of Event 1 action
95
PY
Output change rate limiter (down) [cool-side]
67
XB
Event 2 type
96
OX
Output limiter (high) [cool-side]
68
FB
Event 2 channel setting
97
OY
Output limiter (low) [cool-side]
69
WB
Event 2 hold action
98
GB
AT bias
6A
LG
Event 2 interlock
99
G3
AT cycles
6B
HB
Event 2 differential gap
9A
OP
Output value with AT turned on
6C
TG
Event 2 delay timer
9B
OQ
Output value with AT turned off
6D
OB
Force ON of Event 2 action
9C
GH
AT differential gap time
6E
XC
Event 3 type
9D
KC
Proportional band adjusting factor [heat-side]
6F
FC
Event 3 channel setting
9E
KD
Integral time adjusting factor [heat-side]
70
WC
Event 3 hold action
9F
KE
Derivative time adjusting factor [heat-side]
71
LH
Event 3 interlock
A0
KF
Proportional band adjusting factor [cool-side]
72
HC
Event 3 differential gap
A1
KG
Integral time adjusting factor [cool-side]
73
TE
Event 3 delay timer
A2
KH
Derivative time adjusting factor [cool-side]
74
OC
Force ON of Event 3 action
A3
P6
Proportional band limiter (high) [heat-side]
75
XD
Event 4 type
A4
P7
Proportional band limiter (low) [heat-side]
76
FD
Event 4 channel setting
A5
I6
Integral time limiter (high) [heat-side]
77
WD
Event 4 hold action
A6
I7
Integral time limiter (low) [heat-side]
78
LI
Event 4 interlock
A7
D6
Derivative time limiter (high) [heat-side]
79
HD
Event 4 differential gap
A8
D7
Derivative time limiter (low) [heat-side]
7A
TF
Event 4 delay timer
A9
P8
Proportional band limiter (high) [cool-side]
7B
OD
Force ON of Event 4 action
AA
P9
Proportional band limiter (low) [cool-side]
7C
XS
CT ratio
AB
I8
Integral time limiter (high) [cool-side]
7D
ZF
CT assignment
AC
I9
Integral time limiter (low) [cool-side]
7E
ND
Heater break alarm (HBA) type
AD
D8
Derivative time limiter (high) [cool-side]
7F
DH
Number of heater break alarm (HBA) delay times
AE
D9
Derivative time limiter (low) [cool-side]
80
XN
Hot/Cold start
AF
V2
Open/Close output neutral zone
81
SX
Start determination point
B0
SY
Action at feedback resistance (FBR)
input error
82
XL
SV tracking
B1
FV
Feedback adjustment
83
OT
MV transfer function
B2
TN
Control motor time
84
XE
Control action
B3
OI
Integrated output limiter
85
PK
Integral/derivative time decimal point position
B4
VS
Valve action at STOP
86
KA
Derivative action
B5
KI
ST proportional band adjusting factor
87
KB
Undershoot suppression factor
B6
KJ
ST integral time adjusting factor
88
DG
Derivative gain
B7
KK
ST derivative time adjusting factor
89
IV
ON/OFF action differential gap (upper)
B8
SU
ST start condition
8A
IW
ON/OFF action differential gap (lower)
B9
Y7
Automatic temperature rise group
8B
WH
Action (high) at input error
BA
RT
Automatic temperature rise dead time
8C
WL
Action (low) at input error
BB
R2
Automatic temperature rise gradient data
8D
OE
Manipulated output value at input error
BC
NS
EDS transfer time decimal point position
8E
OF
Manipulated output value at STOP mode
[heat-side]
BD
NV
Output average processing time for EDS
8F
OG
Manipulated output value at STOP mode
[cool-side]
BE
NW
Responsive action trigger point for EDS
90
PH
Output change rate limiter (up) [heat-side]
BF
HU
Setting change rate limiter unit time
91
PL
Output change rate limiter (down) [heat-side]
C0
RU
Soak time unit
92
OH
Output limiter (high) [heat-side]
C1
SH
Setting limiter (high)