![RKC INSTRUMENT CB100 Series Скачать руководство пользователя страница 206](http://html.mh-extra.com/html/rkc-instrument/cb100-series/cb100-series_connection-manual_1466586206.webp)
Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
206
15F)
•
1:1 Connection
•
1:n Connection
• We recommend the TM4P-66P from HIROSE ELECTRIC CO., LTD. as the modular
connector.
• To use the External Device's COM.PORT, pair COM.PORT1 with COM.PORT2, and
COM.PORT3 with COM.PORT4.
2
1
T/R(B)
T/R(A)
3
SG
120
Ω
(1/2W)
NC
3
DATA -
2
SG
5
4
ERA
NC
ERB
7
9
CSB
6
FG
DATA+
1
CSA
8
Shell
Display
Shield
D-Sub 9 Pin (socket)
Signal name
Pin
COM.PORT1
or COM.PORT3
modular connector
Terminal block
External Device side
Signal name
Pin
External
Device
Termination
resistance
Connect the terminating
resistor connector
W-BW-01 for Z-COM
to COM.PORT2
or COM.PORT4.
Display side
2
1
T/R(B)
T/R(A)
3
SG
120
Ω
(1/2W)
NC
3
DATA -
2
SG
5
4
ERA
NC
ERB
7
9
CSB
6
FG
DATA+
1
CSA
8
W-BF-02
Shell
Display
Shield
D-Sub 9 Pin (socket)
Signal name
Pin
COM.PORT1
or COM.PORT3
modular connector
Terminal block
External Device side
Signal name
Pin
COM.PORT2
or
COM.PORT4
External
Device
COM.PORT1
or
COM.PORT3
External
Device
Termination
resistance
Connect the terminating
resistor connector
W-BW-01 for Z-COM
to COM.PORT2
or COM.PORT4.
Display side