Product Manual | Lynx™ Shielded Dual‑Relay Output Module OR2‑M
RJG, Inc.
13
eDART
VERSION 10.XX SOFTWARE
1.
Part Sorting
The OR2‑M must be set up in Machine
Setup>Outputs>Sorting, Alarm Settings, and
Part Diverter Controls functions in order to sort
parts.
Assign the OR2‑M as a Sorting Output sensor
type; choose the desired sorting type (Failsafe
Good Part Output, Traditional Output, or
Individual Cavity Sorting) from the drop‑down
menu. Individual Cavity sorting setup must be
completed in Mold Setup>Outputs, and can be
tested in Mold Setup>Test Outputs.
Traditional Output sorting is based on process
alarm limits. The Process Setup>Alarm Limits
tool is used to set alarms on specific process
values; the software uses the set process values
to sort the parts. Create an alarm in the Alarm
Limits tool. Set up soring actions in Process
Setup>Sorting Actions.
In addition, the OR2‑M can be configured
in the Machine Setup>Outputs and Process
Settings>Control Settings tool to activate
an alarm or stop the machine if an excessive
amount of rejects are produced. Assign the
OR2‑M as a Sorting Output type in Machine
Setup>Outputs; choose the Excessive Rejects
sensor location from the drop‑down menu.
Define the reject and consecutive cycle limits in
Process Settings>Control Settings.
2.
Injection Enable
The OR2‑M must be set up in Machine
Setup>Outputs>Control to control injection.
Assign the OR2‑M as a Control type in Machine
Setup>Outputs tool; choose the Inject Enable
location from the drop‑down menu.
The injection enable function allows the
connected relay contact closer to stay closed
as long as the system is operating properly;
if a failure occurs the output opens, and the
machine stops to prevent any damage.
3.
V
→
P
The OR2‑M is set up to transfer the injection
molding machine from the velocity stage to the
pressure stage in the cycle. The OR2‑M must
be set up in Machine Setup>Outputs.
To test if the input is detected by the machine,
use the Machine Setup>Tests Output function.
Select V
→
P Transfer, then press the Test button
and check the press controller’s diagnostic page
for changes in the input. The
eDART
disables the
test button when the press is cycling.
If the inputs are correct and detected by the
machine, perform the following to ensure the
correct function:
Set up a process (DECOUPLED MOLDING
®
II
or III) with transfer from pressure to hold based
on the machine’s screw position.
Make sure the process ends with little cushion,
likely bottoming out shortly after transfer—this
will prevent mold damage if the transfer does
not work.
TESTING (
continued
)
Содержание Lynx OR2-M
Страница 2: ...PRINT DATE 11 11 2019 REVISION NO 1 ...
Страница 6: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual iv RJG Inc ...
Страница 8: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual vi RJG Inc ...
Страница 14: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual 6 RJG Inc ...
Страница 18: ...Lynx Shielded Dual Relay Output Module OR2 M Product Manual 10 RJG Inc ...
Страница 33: ......