Product Manual | Lynx™ Shielded Dual‑Relay Output Module OR2‑M
RJG, Inc.
9
WIRING (
continued
)
RJG, Inc. recommends the user of the included
quench‑arcs with dry contacts, preferably
installed across the load—however, the
quench‑arcs may also be placed across the
contacts by attaching to the cable pigtails—refer
to the figure below for installation.
Quench‑arcs
Quench‑arcs increase relay life and
reduce electromagnetic interference
(EMI) emissions. It is preferred that the
quench‑arcs are attached across the
load. However, the quench‑arcs may
alternately be placed across the contacts
by attachment to the cable pigtails.
INSTALLATION SPECIFICATIONS (
continued
)
CONNECTIONS
Connect the OR2‑M to the shielded
sequence module ID7‑M‑SEQ—or shielded
communications module DIN/LX‑D—using the
integrated, side‑mount amphenol connector.
Connect the C‑OR2‑M‑3M cable to the OR2‑M
module.
QUENCH-ARC
OR2-M MODULE
C-OR2-M-3M CABLE
C-OR2-M-3M CABLE
NC
NC
NO
NO
24 V SUPPLY
24 V SUPPLY
QUENCH-ARC