ROOF ASSEMBLY
SELECT:
12 x 1.600 m Roof Sheets
2 x 3.055 m Spouting
4 x 1.600 m Barges
1 x 1.800 m Ridge Flashing
1 x 3.020 m Ridge Beam
2 x 0.200 m Jack Studs
8 x 75mm Screws
76 x 40mm Weatherseal Nails
66 x Rivets
11
IMPORTANT—FOR SHEDS WITH OPTIONAL CLEAR ROOF
PANEL
Assemble as below, making sure that the Clear Roof Sheets over-
lap the standard roof sheets on both sides.
The Clear Roof Panel must be secured to the Top Plate and the
Ridge Beam. Pre drill and fasten with the 40mm weatherseal nails
provided.
.
STEP 1:
Place the Ridge Beam on a level surface and use 2 x 75mm screws
to secure the Jack Studs to the underside of the Ridge Beam, one at
each end (fig. 1).
Turn the Ridge Beam /Jack Stud assembly over and place it on the
timber Top Plate in a central position.
Secure with 2 x 75mm screws through the top of the Jack Studs
into the Timber Top Plate (fig. 2).
Check that the shed is sitting level and square and that the diagonal
Top Plate measurements are the same.
fig. 1
JACK STUD
TOP PLATE
RIDGE BEAM
fig. 2
fig. 3
15mm
JACK STUD
RIDGE BEAM
TOP PLATE
ROOF SHEET
SIDE
WALL
FRONT WALL
BACK WALL
SIDE
WALL
TOP PLATE
BOTTOM PLATE
RIDGE
BEAM
SIDE
WALL
FRONT WALL
BACK WALL
SIDE
WALL
TOP PLATE
BOTTOM PLATE
STEP 2:
Position the first Roof Sheet so that the top of the sheet is at the
centre of the Ridge Beam and the side of the sheet over hangs the
end of the Ridge Beam (fig .3). Using 1 x weatherseal , nail in the
top corner. Nail the lower corner ensuring 15mm overhang.
Position the remaining front Roof Sheets and rivet them together as
shown
Nail the last sheet to the Ridge Beam and the Top Plate ensuing
the Roof Sheet overhangs the end of the Ridge Beam and the Top
Plate by 15mm.
Nail front Roof Sheets to Ridge Beam and Top Plate (1 x weather-
seal per pan, fig.4) ensuring Ridge Beam and Top Plate are
straight.
Repeat with remaining roof sheets
fig. 4
Содержание Duratuf SENTRY SHEDS SG3030
Страница 1: ...ASSEMBLY INSTRUCTIONS SG3030 BASE SIZE 3 020m x 3 020m ...
Страница 2: ......
Страница 15: ......