3-6 Riverstone Networks RS 8000/8600 Switch Router Getting Started Guide
Installing the Hardware
Hardware Installation
3.3.4
Installing a DC Power Supply
The following section explains how to install DC power supplies, and explains the differences between DC supplies
for the RS 8000 and RS 8600.
Warning
The RS 8000/8600 with DC power supplies should be installed only in
Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or
the like) in accordance with Articles 110-26 and 110-27 of the 1999 National
Electrical Code ANSI/NFPA 70.
DC Power Supply Installation Procedure
To install a DC power supply on the RS 8000 or RS 8600:
1.
Ensure that the DC power supply is not powered on.
2.
If a cover plate is installed over the DC power supply slot, use a #2 Phillips-head screwdriver to
remove it. If you are replacing a power supply, remove the power cables from the supply you are
replacing, loosen the captive screws on the power supply’s front panel, then pull the supply out of
the chassis.
3.
Slide the DC power supply all the way into the slot, firmly but gently pressing to ensure that the pins
on the back of the power supply are completely seated in the backplane.
4.
Use a #2 Phillips-head screwdriver to tighten the captive screws on each side of the DC power
supply to secure it to the chassis.
5.
Attach the power leads (12-gauge to 14-gauge) to the terminal blocks on the front of the unit. To
attach a power lead, loosen the terminal screw, insert the exposed end of the power lead, and tighten
the terminal screw.
6.
Connect the safety ground wire (12-gauge to 14-gauge) to a reliable earth ground.
7.
Connect the DC input wiring to a DC power source.
DC Power Supply Specifications
The following table lists the physical specifications for the RS 8000/8600 DC power supplies.
Table 3-4
Physical Specifications for DC Power Supply
Specification
RS 8000
RS 8600
Dimensions
11.00" (L) x 7.70" (W) x 2.55" (H)
12.15" (L) x 7.70" (W) x 5.05" (H)
Weight
6.5 lb (2.95 kg)
12.0 lb (5.45 kg)
Power Output
300 W
600 W
Voltage Range
36 to 72 V, 14 A @ 48 V nominal
36 to 72 V, 27 A @ 48 V nominal
Содержание RS 8000
Страница 1: ...36 005 15 Rev 0A RS 8000 8600 Switch Router Getting Started Guide Release 9 3...
Страница 14: ...xiv Riverstone Networks RS 8000 8600 Switch Router Getting Started Guide...
Страница 18: ...xviii Riverstone Networks RS 8000 8600 Switch Router Getting Started Guide...
Страница 24: ...1 2 Riverstone Networks RS 8000 8600 Switch Router Getting Started Guide Related Documentation About This Guide...
Страница 108: ...3 22 Riverstone Networks RS 8000 8600 Switch Router Getting Started Guide Installing the Hardware Hardware Installation...
Страница 152: ...B 2 Riverstone Networks RS 8000 8600 Switch Router Getting Started Guide CONSIDERACIONES DE SEGURIDAD...