38
EN
ERROR 55
–
WELDING CYCLE INTERRUPTED BY THE OPERATOR
Probable cause
:
The operator pressed the STOP pushbutton
Solution:
Repeat the welding with another coupler
ERROR 60
–
SHORT CIRCUIT
Probable cause
:
The coupler is damaged
Solution
:
Repeat the welding with another coupler
ERROR 65
–
LACK OF VOLTAGE AT THE POWER SOURCE
Probable cause
:
Power supply cable has been disconnected
Solution
:
Plug in the power supply cable
Probable cause
:
The voltage supply was interrupted
Solution
:
Wait until the service is restored
Probable cause
:
The safety microswitches are on.
Solution
:
Engage the safety microswitches
ERROR 70
–
HARDWARE ERROR
Solution
:
Contact an authorized service center.
ERROR 75
–
RESISTANCE MISMATCH
Probable cause
:
the resistance value on the barcode is different from the measured value.
Solution
:
Scan the barcode again.
Check the terminal connections. Use another coupler.
ERROR 80
–
OVERHAUL EXPIRED
Solution
:
Contact an authorized service center.
ERROR 90
–
UNSTABLE CURRENT WITHDRAW FROM COUPLER
Solution
:
The coupler coils can be damaged or the cable leads can be lose. Check the
leads and try to replace the coupler. This error does not appear in the very beginning of
the welding cycle
Attention please!
If the “
ATTENTION! FREE MEMORY: 5
“message
is displayed at the ignition
of the machine, follow the procedure
:
“Reset welding reports” of previous chapters. If you
don’t do this and continue to use the machine, the last report will replace the first one in
memory, then the second report will be replaced, and