The Occupational Safety and Health Administration requires that, in addition to posting safety warnings and
barricading the work area, the power supply has been locked in the OFF position or disconnected. It is mandatory
that an approved lockout device is utilized. An example of a lockout device is illustrated. The proper lockout
procedure requires that the person responsible for the repairs is the only person who has the ability to remove the
lockout device.

In addition to the lockout device, it is also a requirement to tag the power control in a manner that will clearly note
that repairs are under way and state who is responsible for the lockout condition. Tagout devices have to be
constructed and printed so that exposure to weather conditions or wet and damp locations will not cause the tag to
deteriorate or become unreadable.

Rite-Hite Corporation does not recommend any particular lockout device, but recommends the utilization of an
OSHA approved device (refer to OSHA regulation 1910.147). Rite-Hite Corporation also recommends the review and
implementation of an entire safety program for the Control of Hazardous Energy (Lockout/Tagout). These regulations
are available through OSHA publication 3120.

This is the highest level statement. Failure to

follow the listed instructions will most likely

result in severe injury or death.

IMPORTANT is used to draw attention

to a procedure that needs to be followed to

prevent machine or property damage.

When working with electrical or electronic

controls, make sure that the power source has

been locked out and tagged according to OSHA

regulations and approved local electrical codes.

This is a statement of serious hazard. Failure to

follow the listed instructions could place the

individual at risk of serious injury or death.

The statements used with this level of 

warning deal with a safe operating 

procedure. If the procedure is ignored, the

possibility of personal injury may exist.

FIGURE 1 - LOCKOUT/TAGOUT

Содержание DOK-LOK VBR-600

Страница 1: ...0 Dok Lok Vehicle Restraint Installation Manual This Manual Covers Restraints Built After Serial Numbers VB6001000 and up PRINTED IN U S A RITE HITE PRINT SHOP PUBLICATION NO 1327 JANUARY 2014 MADE IN...

Страница 2: ...2 Pub No 1327 January 2014 RITE HITE VBR 600 DOK LOK Installation Manual NOTES...

Страница 3: ...ion exists The DOK LOK vehicle restriant is operated by pressing push buttons on an inside control panel NOTICE TO USER Your local Rite Hite representative provides a Planned Maintenance Program P M P...

Страница 4: ...o deteriorate or become unreadable Rite Hite Corporation does not recommend any particular lockout device but recommends the utilization of an OSHA approved device refer to OSHA regulation 1910 147 Ri...

Страница 5: ...ulic cylinder on the dock leveler is not over the opening of the Dok Lok cylinder clevis needs to be shimmed to pit floor to support hydraulic dock leveler 6 Route Dok Lok hydraulic hoses thru the bac...

Страница 6: ...unction box Ensure that the switch cable has enough slack to travel with the barrier through the entire locking range See figure 4 6 Pub No 1327 January 2014 RITE HITE VBR 600 DOK LOK Installation Man...

Страница 7: ...de lights 15 inside light control box inside sign disconnect supplied by others place control box where best suited within arms reach at eye level near door opening dock seal 5 Ref FIGURE 6 SUGGESTED...

Страница 8: ...t may produce condensation c Spacers should be installed between the enclosure and the wall to provide tempature insulation and air flow 13 Connect wiring as indicated by the Electrical Schematic and...

Страница 9: ...L B RED WIRES WHITE WIRE WHITE WIRE DETAIL B IN LEVELER PIT SUPPLIED BY OTHERS JUNCTION BOX RIG SENSOR WIRE SECURE TO PIT FLOOR AND LEAVE 20 OF SLACK SO BARRIER CAN TRAVEL FULL RANGE STORED SENSOR WIR...

Страница 10: ...D R G LOCK UNLOCK ISA2 HS 3 HS 2 HS 1 1 L1 L2 MCOM M 1 SCOM SOL1 SOL2 CR4 CR5 250v 1A Fast Blow 250v 15A Slow Blow M 1 SOL1 SOL2 BLK WHT 120 VAC 0 23 AMPS BLK WHT 120 VAC 0 23 AMPS Solenoid 1 Position...

Страница 11: ...RIER CAN TRAVEL FULL RANGE STORED SENSOR WIRE SECURE TO PIT FLOOR WIRE TO POSITION CYLINDER FLOAT SOLENOID SOL 2 WIRE TO POSITION CYLINDER EXTEND SOLENOID SOL 1 WIRE TO DIVERT SOLENOID SOL 3 SW1 SW1 V...

Страница 12: ...M M 1 SCOM SOL1 SOL2 CR4 CR5 250v 1A Fast Blow 250v 15A Slow Blow M 1 SOL1 SOL2 BLK WHT 120 VAC 0 23 AMPS BLK WHT 120 VAC 0 23 AMPS Solenoid 1 Position Cyl Extend Solenoid 2 Position Cyl Float 10 Sol...

Страница 13: ...r extends Release LOCK button cylinder will retract 19 Press and Hold the UNLOCK button until the main and positioning cylinders extend Release unlock button main cylinder will retract 20 Tighten lift...

Страница 14: ...LY TOP FRONT RIGHT SIDE VIEW BOTTOM BACK RIGHT SIDE VIEW DOK LOK Main Cylinder Port DOK LOK Position Cylinder Port Leveler Lip Block Solenoid SOL 4 Leveler Ramp Cylinder Out Port DOK LOK Position Cyli...

Страница 15: ...NOTES Pub No 1327 January 2014 15 RITE HITE VBR 600 DOK LOK Installation Manual...

Страница 16: ...and operated within their rated capacities and or specified design parameters and not otherwise abused Periodic lubrication and adjustment is the sole responsibility of the owner This warranty is Rit...

Отзывы: