L.
Install Cover
- Replace the top cover and secure to base.
Do not over tighten bolts.
M.
Seal the Base
- After the unit is completely installed, apply a bead of caulking around the base of the fountain
to ensure no wind enters through the base of the unit.
NOTE: sealing the bottom of the unit from cold air
is an important aspect of the unit's thermal performance.
Supplemental Heat
In some cases you may wish to add supplemental heat to the Thrifty King. Immersion heater part #16311 should
be placed flat on the bottom of the valve chamber. Ensure that the placement of the heater and its power cable do
not interfere with the motion of the float assembly. Supply line heat cable part #16276 should wrap around the
valve, and follow the supply line down the riser tube. Use nylon ties to anchor the heat cable to the supply line.
NOTE:
Serial number or date code is found on underneath side of top red valve cover. This
information will be needed for warranty.
Ritchie Valves
Ritchie valves come in three pressure ratings as shown. The
Thrifty King for swine uses the smaller 1/2" valves. A red
valve is standard with all Thrifty King for Swine units. This
valve accommodates most common operating pressures, and
provides more than adequate water flow rates for the number
of animals that could be drinking at any one time from these
troughs.
Your individual situations may require a change from the standard valve supplied with your fountain, see your
Ritchie Dealer if this is needed.
1/2”
Part #
GPM
Pressure Range
White
12574
4.8
Low, 5-40 psi
Red
12575
3.4
Moderate, 40-60 psi
Green
13597
1.45
High, 60-80 psi
Thrifty King for Swine Product Specifications
HG 2
HG 4
Drink Height
8
8
Width 20
31.25
Length 31.25
31.25
Shipping Weight
50
70
Operating Capacity
2 Gallons
5.2 gallons
Herd Capacity
80 Hogs
160 Hogs
Thrifty King Swine Instruction Manual
3